You have already made the important decision of choosing your U.S. Stove Pellet Burning Room Heater; now 

your next step is to determine where to install your new pellet stove heater. To get the most efficient use of re-

circulated heat, you should consider a room that is centrally located within your home. Choose a room that 

is large and open. It is Extremely Important to maintain proper clearances from any combustible surfaces or 

materials in the room where your heater will be located. You can find proper clearance measurements in this 

manual and on the rating label of your pellet stove. The pellet stove can be vented through an exterior wall or 

into an existing masonry or metal chimney if “PL” or “L” vent pipe is used throughout existing chimney. Venting 

can pass through the ceiling and roof if approved pipe is used. Where passage through a wall, or partition of 

combustible construction is desired, the installation must conform to CAN/CSA-B365.

• 

DO NOT OBTAIN COMBUSTION AIR FROM THE ATTIC, GARAGE OR ANY OTHER UNVENTILATED AREA. YOU MAY 

OBTAIN COMBUSTION AIR FROM A VENTILATED CRAWL SPACE.

• 

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.

• 

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER HEATER, FURNACE OR APPLIANCE.

•  INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.

• 

ONLY USE APPROVED MATERIAL FOR INSTALLATION, FAILURE TO DO SO MAY RESULT IN PROPERTY DAMAGE, 

BODILY INJURY, OR EVEN DEATH.

This appliance is certified for use with listed 3 inch or 4 inch “PL” or “L” pellet venting products. The use of other 

components other than stated herein could cause bodily harm, heater damage, and void your warranty.

HORIZONTAL EXHAUST VENT INSTALLATION

1. 

Locate your pellet stove in a location which meets the requirements of this manual, but in an area where it 

does not interfere with the house framing, wiring, etc.

2. 

Install a non-combustible hearth pad underneath the pellet stove. This pad should extend at least 6” (152 

mm) in front of the unit.

3. 

Place the pellet stove approximately 15” (381 mm) away from the interior wall.

4.  Locate the center of the exhaust pipe of your unit. This point should then be extended to the interior wall of 

your house. Once you have located the center point, on the interior wall, cut a 7” (175 mm) diameter hole 

through the wall.

5. 

The next step is to install the wall thimble, refer to the instructions which come with the wall thimble for this 

step. 

6. 

Install the appropriate length of exhaust vent pipe into the wall thimble. See steps 11 and 12 when determining 

the correct length of exhaust vent to use. 

7.  Outside Fresh Air is Mandatory when installing this pellet stove room heater in airtight homes and mobile 

homes. 

Be sure that the outside air vent has an approved cap on it to prevent rodents from entering. Be sure 

to install in location that won’t become blocked with snow, etc.

8. 

The air intake pipe is equipped with a butterfly valve  that is preset to maximum air intake. For optimum 

operating  efficiency  you  may  calibrate  the  butterfly  valve  to  provide  less  intake  air. 

Caution: Too much 

restriction on the intake air will cause dirtier burn, therefore, will require more frequent cleaning. 

Connect the 

exhaust vent pipe to the exhaust outlet of your pellet stove.

 

 

 

 

 

9.  Secure all vent joint connections with 3 screws. Seal the exhaust vent joint connections with high temperature 

silicone sealant.

10. 

Push the unit straight back to the interior wall, being sure to maintain the minimum clearances to combustibles 

6” (152 mm) to the back of the unit. Seal the annular space of the wall thimble and around the vent pipe 

with high temperature silicone sealant.

11.  The exhaust vent pipe must extend at least 12” (300 mm) out past the exterior wall. Seal the annular space 

of the wall thimble and around the vent pipe with high temperature silicone sealant.

12.  Install an approved horizontal termination cap or if necessary install a 90° elbow and appropriate length of 

vertical venting. An approved vertical vent cap is recommended.

-7-

Содержание Ashley AP5660PE

Страница 1: ...bject to change without notice ALL PICTURES SHOWN ARE FOR ILLUSTRATIVE PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENT This unit is not intended to be used as a primary source of heat...

Страница 2: ...not feed pellets under these circumstances and a safety concern may arise from sparks or fumes entering the room Allow the stove to cool before performing any maintenance or cleaning Ashes must be di...

Страница 3: ...ellets that comply with Pellet Fuels Institute PFI standards You can only burn premium grade pellets in this pellet heater minimum of 40 lbs density per cubic feet 1 4 to 5 16 diameter length no great...

Страница 4: ...led on a combustible floor it is mandatory that a 1 2 13 mm thick non combustible hearth pad be installed under the heater The non combustible hearth pad must extend at least 6 152 mm beyond the fuel...

Страница 5: ...ns PELLET VENT TYPE A UL listed 3 inch or 4 inch type PL pellet vent exhaust system must be used for installation and attached to the pipe connector provided on the back of the stove use a 3 inch to 4...

Страница 6: ...e G Minimum 2 foot 0 61m clearance below eves or overhang H Minimum 1 foot 0 3m clearance horizontally from combustible wall I Must be a minimum of 3 foot 0 091m above the roof and 2 foot 0 61m above...

Страница 7: ...derneath the pellet stove This pad should extend at least 6 152 mm in front of the unit 3 Place the pellet stove approximately 15 381 mm away from the interior wall 4 Locate the center of the exhaust...

Страница 8: ...3ft 0 91m to get above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is...

Страница 9: ...ed for installation into a mobile home HEARTH PAD FLOORING GROUND WIRE DIRECTLY TO METAL CHASSIS STEEL FRAME 1 4 LAG BOLTS SECURELY FASTENED 69FAK OUTSIDE AIR SUPPLY OPTIONAL UNLESS INSTALLING IN A MO...

Страница 10: ...ton changes the two digit display from degrees Celsius to degrees Fahrenheit D MODE M T BUTTON The Mode of the stove can be switched between manual and controlled with a Thermostat Separate LEDs to th...

Страница 11: ...arefully prescribed rate Any additional fuel introduced by hand will not increase heat output but may seriously impair the stoves performance by generating considerable smoke Do not burn wet pellets T...

Страница 12: ...re to go out OPENING DOOR If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down If the stove shuts down push the On Off button to re sta...

Страница 13: ...r opening the exhaust system for any inspection cleaning or maintenance work Never perform any inspections cleaning or maintenance on a hot stove Do not operate stove with broken glass leakage of flue...

Страница 14: ...h into the room DO NOT VACUUM HOT ASH CLEANING Heat Exchanger Tubes Your Pellet Stove Room Heater is designed with a built in heat exchanger tube cleaner This should be used every 2 or 3 days to remov...

Страница 15: ...LEAN ANNUALLY 1 Remove the front glass by releasing the two latches attaching it to the unit They are located behind the right side panel 2 Remove the two side brick panels 3 Remove the two interior s...

Страница 16: ...ove the exhaust blower from the exhaust duct and clean out the internal fan blades as part of your fall start up PAINTED SURFACES Painted surfaces may be wiped down with a damp cloth If scratches appe...

Страница 17: ...lso a good time to give the entire stove a good cleaning throughout SPRING SHUTDOWN After the last burn in the spring remove any remaining pellets from the hopper and the auger feed system Scoop out t...

Страница 18: ...decorative logs in there correct location Your decorative logs should come in place however if this is not the case the following steps depicts the correct location STEP 2 Place log into correct posit...

Страница 19: ...ip Check to see if a surge protector is being used on the stove If not recommend one to the customer High Limit Switch is malfunctioning If the other items check out OK replace the high limit switch D...

Страница 20: ...ad The Proof of Fire POF thermodisc has malfunctioned Temporarily bypass the POF thermodisc by disconnecting the two wires and connecting them with a short piece of wire Then plug the stove back up If...

Страница 21: ...or signs of damage such as burrs rough spots or grooves cut into the metal that could have caused a jam The auger motor has failed Remove the auger motor from the auger shaft and try to run the unit I...

Страница 22: ...light comes on as designed Possible Causes Possible Remedies Unplug stove first when possible High limit switch has tripped or is defective Wait for the stove to cool for about 30 45 minutes Locate t...

Страница 23: ...S BLACK TIPS AFTER STOVE HAS BEEN ON FOR A WHILE THE BURNPOT OVERFILLS Possible Causes Possible Remedies Unplug stove first when possible Stove or vent pipe is dirty which restricts airflow through th...

Страница 24: ...Parts List 3 2 6 7 10 12 18 20 21 23 22 24 25 26 27 19 17 16 15 14 13 4 5 9 8 11 1 24...

Страница 25: ...1 8 88163 Brick Panel Center 1 9 88164 Brick Panel Left 1 10 892037 Hearth Trim 1 11 69794 Exhaust Grill 1 12 891540 Latch Door 4 13 80631 PCBA Board 1 14 80549 Pressure Switch 1 15 80601 Switch Hi T...

Страница 26: ...Wiring Diagram CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown 26...

Страница 27: ...Notes...

Страница 28: ...7 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _________________...

Страница 29: ...ice fiable et efficace de votre appareil de chauffage et vous permettre de commander correctement les pi ces de rechange Conservez ce manuel dans un endroit s r pour r f rence future Lors de l criture...

Страница 30: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Страница 31: ...R COMMUNICATIONS CABLE CONSEIL D AFFICHAGE Vue arri re BROWN GRIS BLEU ROSE PURPLE BLANC BLACK SOURCE DE COURANT 120 Volts AC BLACK BLANC ORANGE BLEU RED IGNITOR E1 ALARME DE SURCHAUFFE E2 VIDE ALARME...

Страница 32: ...t Temp 1 16 80606 Moteur Tari re 1 17 80604 Allumeur 1 18 88167 Joint Ventilateur De Convection 1 19 80622 Ventilateur Convection 1 20 891999 Tari re 1 21 891998 Bague 2 22 88166 Joint Ventilateur D c...

Страница 33: ...24 Pi ces De Rechange 3 2 6 7 10 12 18 20 21 23 22 24 25 26 27 19 17 16 15 14 13 4 5 9 8 11 1...

Страница 34: ...RAPIDEMENT FLAMME EST MOLLE DARK ET A TIPS NOIR APR S POELE A T SUR UN TOUT LA pot de combustion d borde Causes possibles Solutions possibles D branchez r chaud premier si possible Tuyau de po le ou d...

Страница 35: ...uses possibles Solutions possibles D branchez r chaud premier si possible Pressostat haute limite a d clench ou est d fectueux Attendez que le po le refroidir pendant environ 30 45 minutes Localisez l...

Страница 36: ...mauvais Affichage clignote E5 Causes possibles Solutions possibles D branchez r chaud premier si possible Le po le se d clenche automatiquement E5 lorsqu il est allum Le capteur T stat est venu sous f...

Страница 37: ...urt morceau de fil Ensuite branchez le po le back up Si le po le est en marche et fonctionne vous devez remplacer le thermodisque POF Ceci est pour tester seulement NE PAS LAISSER LE THERMODISQUE BYPA...

Страница 38: ...utres types de combustibles utilis s cesser de les utiliser imm diatement Surtension ou d une situation hors brun Une surtension pointe ou chute de tension pourrait provoquer la fin de course haute de...

Страница 39: ...les b ches d coratives leur emplacement correct Vos journaux d coratifs devraient venir en place si ce n est pas le cas les tapes ci dessous illustre l emplacement correct TAPE 2 Placez la b che dans...

Страница 40: ...tal 4 Vide pour liminer les cendres du foyer Remarque v rifiez que CENDRES SONT FROID AU TOUCHER AVANT ASPIRATION Certains aspirateurs peuvent fuir les cendres dans la pi ce Votre aspirateur devrait a...

Страница 41: ...c un chiffon humide Si des rayures apparaissent ou si vous souhaitez renouveler votre peinture contactez votre revendeur agr pour obtenir une bo te de peinture appropri e haute temp rature VERRE NETTO...

Страница 42: ...NNUELLEMENT 1 Retirez la vitre avant en lib rant les deux loquets qui la fixent l unit Ils sont situ s derri re le panneau lat ral droit 2 Retirez les deux panneaux de brique lat rale 3 Retirez les de...

Страница 43: ...la pi ce NE PAS ASPIRER LES CENDRES CHAUDES NETTOYAGE Tubes d changeur thermique Votre po le granul s de chauffage de pi ce est con u avec un nettoyeur int gr de tubes d changeur Il doit s utiliser t...

Страница 44: ...ui se combinent l humidit vacu e pour former la cr osote Les vapeurs de cr osote se condensent dans le conduit de chemin e relativement froid ou un feu qui vient de d marrer ou d un feu combustion len...

Страница 45: ...r de chaleur du po le se r chauffe Cela prend habituellement environ 10 minutes de start up SI PO LE MANQUE DE GRANULES Le feu teint et le moteur de la vis et les ventilateurs se d roulera jusqu ce qu...

Страница 46: ...able Pellets peuvent tre cribl s avant d tre plac dans la tr mie pour liminer la plupart des amendes 2 Reliures Certains granul s sont fabriqu s avec des mat riaux de tenir le ensemble ou lier eux 3 H...

Страница 47: ...u niveau 5 de chauffage C TOUCHE C F La touche C F fait passer l affichage deux chiffres des degr s Celsius aux degr s Fahrenheit et vice versa D TOUCHE MODE M T Le Mode de fonctionnement du po le peu...

Страница 48: ...ne maison mobile TAPIS CONDUCTEUR PLANCHER STRUCTURE EN ACIER FIL DE TERRE DIRECTEMENT AU CH SSIS M TALLIQUE TIRE FOND DE 1 4 BIEN SERR S 69FAK APPROVISIONNEMENT EN AIR EXT RIEUR EN OPTION En fonction...

Страница 49: ...s chutes de neige il est recommand que l installation soit plus grand que 3 pi 0 91 m pour obtenir au dessus de la ligne de cong re Cette m me installation peut tre utilis e si votre chauffe eau est e...

Страница 50: ...un tampon de foyer non combustible sous le po le granul s Ce coussin doit d passer d au moins 6 po 152 mm en face de l unit 3 Placez le po le granul s environ 15 po 381 mm de loin de la paroi int rieu...

Страница 51: ...mum 0 3 m 1 pieds d gagement au dessus d une porte ou fen tre qui ouvre C Le minimum de 0 9 m 3 pieds de d gagement de tout b timent adjacent D Le minimum de 2 13 m 7 pieds l autorisation de tout grad...

Страница 52: ...ns une vall e pouvant causer des conditions malsaines ou nuisibles PELLET TYPE D VENT Une liste UL de 3 pouces ou 4 pouces de type culot PL vent syst me d chappement doit tre utilis pour l installatio...

Страница 53: ...s des dommages au chauffage et annuler votre garantie CLOISON ARRI RE Alcove Dimensions 36 35 40 2 6 USA 6 CANADA 8 PROTECTION DE PLANCHER USA 6 CANADA 18 2 PROTECTION DE PLANCHER USA 6 CANADA 8 USA 6...

Страница 54: ...st con u et test avec des granules de qualit sup rieure conformes aux normes du Pellet Fuels Institute PFI Vous ne pouvez br ler que des granules de qualit sup rieure dans ce po le granules densit min...

Страница 55: ...a porte N essayez pas de faire fonctionner l unit avec une vitre cass e Une vitre de remplacement peut tre achet e chez votre revendeur U S Stove de chauffages pour pi ce carburant aux granul s N essa...

Страница 56: ...gences d inspection et d terminer si vous avez besoin d un permis de construire Ces po les granul s de bois pour chauffage de pi ce ont t con us pour tre utilis s aux USA et au Canada et conviennent p...

Отзывы: