background image

8

OPERATING INSTRUCTIONS

Check and Fill the Fuel Hopper with Pellets: 

This Pellet Stove is available as a freestanding unit or as a fireplace insert.  There is a different method for filling the hopper for each type 

of heater:

Ø

 To check and fill the hopper of the freestanding heater, simply lift the hopper door, visually check the hopper and add pellets  

 

 

when needed.

Ø

 To check and fill the hopper of the insert heater, pull hopper lid forward, visually check the hopper and    

 

 

 

add pellets when needed.

CAUTION: DO NOT OVERFILL THE PELLET FUEL HOPPER.  AS A SAFETY PRECAUTION, AUGER WILL NOT OPERATE AT ANY 

TIME WHEN FUEL HOPPER DOOR IS OPEN. 
Pre-start Check-up:

Make sure that all parts of the pellet stove room heater are cool before proceeding.  Remove the burn pot and clean out any ash debris. 

Be sure to re-install the burn pot in the correct position (see page 29).

The blowers and automatic fuel supply are controlled from a panel located on the right hand side of the stove.

Note:  Your Pellet Stove may omit an odor as oil residue from the manufacturing process burns off and the high temperature 

paint cures. You can minimize this effect by running a smaller fire for the first few hours of operation.  Avoid placing any items 

on the stove top during this period as the stove’s paint could be permanently damaged.
Lighting Instructions:
ATTENTION: Viewing door must be securely latched to ensure proper stove operation.  Push door-handle downward until latch 

is fully engaged; you will feel the latch engage and hear an audible click. 

When first operating your Pellet Stove, depress the MODE button until the LED indicator above MANUAL lights up. This will engage 

MANUAL mode and provide you with full control of the heater’s control board functions and allow you to familiarize yourself with how the 

heater works.  The heat level for T-STAT mode can only be set when the control is in the Manual Mode.

Starting Up The Pellet Stove Room Heater:

Whenever operating the pellet stove for first time, or if the stove runs out of pellets, it is necessary to prime the auger with pellet fuel.  To 

do this, Press and Hold the AUGER Button for Approximately 3 Seconds until the AUGER LED illuminates.  This procedure will prime the 
auger and then automatically initiate the normal ignition cycle.  

CAUTION: Do not use this procedure for normal startup.  To do so would cause excessive fuel build-up in the burn pot.

For normal startup with pellet fuel in the auger, press and release the On/Off button. The LED indicator light above the On/Off button will 

alternately flash green then red to indicate that the start-up cycle has begun. The light above the Auger button will flash intermittently to 

indicate the activation of the auger feeding the pellets into the burn pot.  The electric igniter will also be activated at this time.  The igniter 
takes a few minutes to come up to temperature in order to ignite the pellets in the burn pot.  It will normally take between 4 minutes and 

8 minutes for pellets to ignite. 

NOTE: If pellets do not ignite within 12 minutes the heater will shut down, requiring you to turn on the heater and repeat the 

start-up process.

When the pellets have ignited and flame has been established, the start-up cycle will end; this procedure takes between 8 and 12 minutes.  

If the control is set to Manual Mode, it will now default to the heat level setting the last shutdown time.  If the control is set to T-STAT Mode, 
the heat output will coincide to the commands from the thermostat.

Auger: 

As explained in the starting up step, this button is only served to start up the pellet stove in lieu of the on/off button when there are no 

pellets in the auger.

Circulation Air Flow:

Your pellet stove room heater features circulation air flow which will change in accordance with the heat setting.  Circulation air flow will be 

at its maximum setting when the heat setting is also at maximum and subsequently will be at its minimum setting when the heat setting is 

at minimum. If you desire to operate the circulation fan at its maximum setting regardless of heat setting, you may do so by pressing the 
FAN button.

Auger Trim:

When operating at Heat Level 1, if the flame goes out or the heat output is too high on the minimum heat level setting, use the AUGER 

TRIM button to make adjustments. See the AUGER TRIM button description on page 11.

Shutting Down Your Pellet Stove Room Heater: 

Turn off the heater by pressing the On/Off button. The stove will enter the shutdown cycle and the pellets will stop feeding into the burn pot 

to allow the fuel in the burn pot to be combusted and consumed. During this period, the exhaust blower and circulation fan will continue to 

operate until the flames are out and the heater has cooled down.  When the heater has cooled down to its pre-set level, it will shut down 

completely.

CAUTION: NEVER TURN OFF THE HEATER BY UNPLUGGING OR DISCONNECTING ITS ELECTRICAL POWER SOURCE. DOING SO 

WILL CAUSE THE HEATER TO SKIP THE PROPER SHUTDOWN CYCLE, CAUSING THE HEATER TO OVERHEAT AND THE POSSIBLE 

RELEASE OF SMOKE INTO THE HOUSE.

Содержание 5560

Страница 1: ...ay result For everyone s safety FOLLOW all Installation and Operating Directions Never use makeshift compromises during the installation of this appliance Contact your local building or fire officials...

Страница 2: ...Instructions 8 9 Thermostat Installation 10 Clearances to Combustibles 11 Installing Your Room Heater 12 19 Mobile Home Installations 20 Insert Pellet Stove Installation 21 24 Vent Termination Locatio...

Страница 3: ...r by 1 1 2 length Ash Content 1 Maximum Premium grade 3 Maximum Standard grade Moisture Content 8 Maximum Heat Content Minimum 8 200 btu s per hour It is important to note that the ash content of the...

Страница 4: ...is maintained Make sure that structural integrity of the home is maintained when passing vent pipes through walls ceilings and roofs It is recommended that the exhaust vent be cleaned bi annually or a...

Страница 5: ...ower outages with battery backup or room air starvation occurs during operation of heater smoke in the house may result This may trigger smoke detectors if they are installed CAUTION DO NOT CONNECT TO...

Страница 6: ...s per hour or 5 1 lbs of fuel per hour Hopper Capacity 55 lbs Dependent upon quality and heating value of pellet fuel DIMENSIONS Figure 1 6 00 in 152 4 mm 13 70 in 348 mm 20 50 in 520 8 mm 10 50 in 26...

Страница 7: ...IMENSIONS continued The minimum installation dimensions of the insert opening are 32 813mm wide x 22 3 4 578mm high x 12 1 4 311mm deep Figure 2 7 10 3 4 11 1 2 13 11 16 39 7 8 29 7 8 23 1 8 3 7 16 20...

Страница 8: ...uel in the auger press and release the On Off button The LED indicator light above the On Off button will alternately flash green then red to indicate that the start up cycle has begun The light above...

Страница 9: ...then Automatically Initiate the Normal Ignition Cycle NOTICE Do not use this procedure for normal startup To do so would cause excessive fuel build up in the burn pot AUGER TRIM Button This Button is...

Страница 10: ...terminal on the rear of the control panel see Figure 4 If you have installed a remote thermostat for your pellet stove and wish to have the heater controlled by that thermostat depress the MODE butto...

Страница 11: ...d be installed under the heater The non combustible hearth pad must extend at least 6 beyond the fuel loading and ash removal openings and at least the depth of the heater plus 6 inches 152mm out in f...

Страница 12: ...s not interfere with the house framing wiring etc 2 Install a non combustible hearth pad underneath the pellet stove This pad should extend at least 6 152mm in front of the unit 3 Place the pellet sto...

Страница 13: ...by Pellet Vent Mfg Combustion Air Intake 6 152mm Clearance to Combustibles Floor Protector 6 152mm Clearance Front Figure 9 6 152 mm Clearance Wall to Back of Unit Wall Thimble Exhaust Vent 45 Elbow...

Страница 14: ...rough the wall 5 Secure all vent joint connections with 3 screws Seal the exhaust vent joint connections with high temperature silicone sealant 6 Install the combustion air intake pipe 7 Install a tee...

Страница 15: ...temperature silicone sealant 6 Locate the center of the exhaust pipe at the back of the unit Line up the center with the same spot on the exterior wall a cut a 7 178mm diameter hole through the wall 7...

Страница 16: ...16 INSTALLING YOUR ROOM HEATER continued SELKIRK DIRECT TEMP VENT SYSTEM FOR PELLET STOVE HEATERS Images courtesy of Selkirk...

Страница 17: ...17 INSTALLING YOUR ROOM HEATER continued SELKIRK DIRECT TEMP VENT SYSTEM FOR PELLET STOVE HEATERS UP AND OUT HORIZONTAL TERMINATION KIT FIGURE 12 Images courtesy of Selkirk...

Страница 18: ...18 INSTALLING YOUR ROOM HEATER continued SELKIRK DIRECT TEMP VENT SYSTEM FOR PELLET STOVE HEATERS STRAIGHT OUT HORIZONTAL TERMINATION KIT FIGURE 12 Images courtesy of Selkirk...

Отзывы: