background image

IMTX200-02

www.ueonline.com

GENERAL

bEFORE  INSTALLING,  CHECK  THE  SENSOR  MODEL  SELECTED  FOR 

COMPATIbILITY  TO  THE  PROCESS  MEDIA  IN  CONTACT  WITH  THE 

SENSOR AND WETTED PARTS.

MISuSE OF THIS PRODuCT MAY CAuSE EXPLOSION AND PERSONAL 

INjuRY.    THESE  INSTRuCTIONS  MuST  bE  THOROuGHLY  READ  AND 

uNDERSTOOD bEFORE uNIT IS INSTALLED.

 

THIS EquIPMENT IS SuITAbLE FOR uSE IN CLASS I, DIvISIONS 

1 & 2, GROuPS A, b, C AND D; CLASS II, DIvISIONS 1 & 2, GROuPS 

E, F AND G; CLASS III; OR NON-HAzARDOuS LOCATIONS ONLY. -40°C 

(-40°F) ≤ Tamb. ≤ 85°C (185°F), 

ENCLOSuRE TYPE 4X.

THIS EquIPMENT IS ATEX CERTIFIED FOR EquIPMENT CATEGORY 2. 

SuITAbLE FOR APPROPRIATE uSE IN GAS zONE 1 AND DuST zONE 

21 APPLICATIONS. 

 

0539 DEMKO 07 ATEX 0715718X

 

 

II 2 G Ex d IIC T5

 

 II 2 D T+90°C

 

-40°C ≤ Tamb. ≤+80ºC, IP66

The  TX200™  transmitter  utilize  a  bonded  foil  strain  gage  bridge  sensor 

to  detect  and  continuously  monitor  pressure  in  a  system.  The  strain  gage 

is a resistive element whose resistance changes with the amount  of  strain 

(pressure) placed upon it. Flexing of the diaphragm causes the resistance 

change and electronically communicates this via a 4 to 20 mA output signal 

or optional 1-5 VDC output signal to a digital meter or gauge, a PLC (pro

-

grammable  logic  controller)  or  other  device.  The  TX200B  is  “fixed  range” 

while the TX200A is “field adjustable” with a 5:1 turndown ratio (see Part II 

– Adjustments).

PROOF PRESSuRE* LIMITS STATED IN THE LITERATuRE AND ON TRANSMITTER 

HOuSING MuST NEvER bE EXCEEDED, EvEN bY SuRGES IN THE SYS-

TEM.  OCCASIONAL OPERATION OF uNIT uP TO MAXIMuM PRESSuRE IS 

ACCEPTAbLE (E.G., START-uP, TESTING). CONTINuOuS OPERATION SHOuLD NOT 

EXCEED THE DESIGNATED OvER RANGE PRESSuRE.

*Proof Pressure
The  maximum  pressure  to  which  a  pressure  sensor  may  be  occasionally 

subjected, which causes no permanent damage (e.g., start-up, testing).  The 

units may require re-adjustment.

THESE PRODuCTS  DO NOT HAvE  ANY FIELD REPLACEAbLE PARTS. 

ANY SubSTITuTION OF COMPONENTS MAY IMPAIR SuITAbILITY FOR 

CLASS I, DIvISION 1.

TX200™ 

Pressure Transmitter

THE EPOXY RESIN SHALL NOT bE SubjECTED TO A TEMPERATuRE 

GrEATEr ThAn 125°C.

Part I - Installation

 

Tools Needed

Adjustable Wrench

MouNTING 

ALWAYS  LOCATE  uNITS  WHERE  SHOCK,  vIbRATION  AND  AMbIENT 

TEMPERATuRE  FLuCTuATIONS  ARE  MINIMAL.  DO  NOT  MOuNT  IN 

AMBIEnT  TEMPErATurE  ArEAs  EXCEEDInG  185°F  (IF  uL/

cuL 

APPrOVAL Is APPLICABLE) Or 80 °C (IF ATEX APPrOVAL Is APPLICABLE). 

IF  SEvERE  PRESSuRE  SuRGES  ARE  EXPECTED,  CONSIDER  THE  uSE  OF  A 

PRESSuRE SNubbER.

uNIT MAY bE MOuNTED IN ANY POSITION. ALWAYS HOLD A WRENCH 

ON THE SENSOR FLATS (PRESSuRE PORT) WHEN MOuNTING uNIT.

WIRING

DISCONNECT ALL SuPPLY CIRCuITS bEFORE WIRING uNIT. ELECTRICAL 

RATINGS STATED IN LITERATuRE AND ON THE TRANSMITTER MuST 

NOT bE EXCEEDED.

EXTErnAL GrOunDInG sCrEW (OPTIOn M460) Is rEquIrED FOr 

NON-METALLIC CONDuIT SYSTEMS. (ATEX REquIREMENT ONLY).

IN ORDER TO MEET EuROPEAN EMC REquIREMENTS, THE TX200™ 

WIRING MuST bE INSTALLED IN A GROuNDED METAL CONDuIT OR 

WITH OTHER SuITAbLE SHIELDING.

ThE  TX200™  TrAnsMITTEr  ACCEPTs  10-36  VDC  FOr  4-20  MA 

OuTPuT unITs AnD 10-30 VDC FOr 1-5 VDC OuTPuT unITs. ThE 

suPPLY VOLTAGE shALL nOT EXCEED 36 VDC FOr 4-20 MA OuTPuT 

unITs  AnD  30  VDC  FOr  1-5  VDC  OuTPuT  unITs.  ThE  suPPLY  MusT  BE 

IsOLATED FrOM MAIns VOLTAGE BY DOuBLE/rEInFOrCED InsuLATIOn.

EARTH GROuND MuST ALWAYS bE CONNECTED TO THE GREEN WIRE 

TO PROvIDE SHIELDING AND ELECTRICAL SAFETY.

WIRE  IN  ACCORDANCE  WITH  LOCAL  AND  NATIONAL  ELECTRICAL 

CODES.  bY THE INSTALLATION, THE WIRES SHALL bE PROTECTED 

AGAINST MECHANICAL DAMAGE. E.G. bY uSE OF A CONDuIT.

U N I T E D   E L E C T R I C 

C O N T R O L S

Installation and Maintenance 

Instructions

Please read all instructional literature carefully and thoroughly before starting.  Refer to the final page for the listing of Recommended 
Practices, Liabilities and Warranties.

IMTX200-02

Содержание TX200

Страница 1: ...ading Berkshire RG6 4UT UK Tel 44 0 118 9311188 Email info able co uk Aberdeen Office Unit 6 Airside Business Park Kirkhill Industrial Estate Dyce Aberdeen AB21 0GT UK Tel 44 0 1224 725999 Email ab able co uk Internet www able co uk e procurement www 247able com Registered in England No 01851002 VAT No GB 417 2481 61 ...

Страница 2: ...p testing The units may require re adjustment These products do not have any field replaceable parts Any substitution of components may impair suitability for Class I Division 1 TX200 Pressure Transmitter The epoxy resin shall not be subjected to a temperature greater than 125 C Part I Installation Tools Needed Adjustable Wrench Mounting Always locate units where shock vibration and ambient temper...

Страница 3: ...would be spanned so that the 4 mA output signal 0 psig and the 20 mA output signal 1500 psig 103 4 bar 2 Connect the transmitter to a 24 volt nominal voltage source through a 100 ohm load resistor Reference Diagram 1A Connect a digital voltmeter across the terminating resistor The output across the resistor will be 100 mVolts mA 3 Zero the transmitter if necessary 4 Turn the Cal switch to the on p...

Страница 4: ...6 0 54 13 7 B G 1 2 female 1 3 8 1 01 25 7 C 7 16 20 SAE male 15 16 0 77 19 6 D HM4 Autoclave male 15 16 1 10 27 9 E HM6 Autoclave male 15 16 1 29 32 8 F LM4 Autoclave male 15 16 1 18 30 0 G LM6 Autoclave male 15 16 1 32 33 5 H G 1 4 male 15 16 1 03 26 2 J G 1 2 male 1 3 8 1 78 45 2 Wire Color Coding Red VDC Black VDC Green Earth Ground Blue 1 5 VDC Output Option M204 only 03 0 to 15 psis 04 0 to ...

Страница 5: ... on a switch can cause damage even on the first cycle Wire unit according to local and national electrical codes using wire size recommended in installation sheet Do not mount unit in ambient temp exceeding published limits LIMITED WARRANTY Seller warrants that the product hereby purchased is upon delivery free from defects in material and work manship and that any such product which is found to b...

Отзывы: