background image

IMP117 11 

1

GENERAL

MISUSE OF THIS PRODUCT MAY CAUSE EXPLOSION 

AND PERSONAL INJURY. THESE INSTRUCTIONS MUST 

BE THOROUGHLY READ AND UNDERSTOOD BEFORE 

DEVICE IS INSTALLED.

PRIOR TO INSTALLATION, CHECK THE WETTED PARTS 

MATERIAL FOR COMPATIBILITY TO THE PROCESS MEDIA. 

Cert number

20190829-E40857 

Applicable Area

North America

Markings

Class I, Div. 2, Groups A, B, C and D; 

Class II, Div. 2, Group F and G, enclosure 

Type 4X

Applicable Standards

ANSI/ISA 12.12.01, UL 508; C22.2 No. 14, 

C22.2 No. 213

Cert number

DEMKO 11 ATEX 1105261X

Applicable Area

Europe (EU)

Markings

II 1 G Ex ia IIC T6 Ga

Applicable Standards

EN IEC 60079-0; EN 60079-11

Cert number

IECEx UL 14.0075X

Applicable Area

International

Markings

Ex ia IIC T6 Ga

-50°C ≤ Tamb ≤ +60°C

Applicable Standards

IEC 60079-0; IEC 60079-11

117 SERIES FOR USE IN CLASS I, DIV. 2, GROUPS A, B, 

C AND D; CLASS II, DIV. 2, GROUPS F AND G; CLASS III; 

OR NON-HAZARDOUS LOCATIONS ONLY. ENCLOSURE 

TYPE 4X, IP66. AMBIENT TEMPERATURE RANGE -50°C 

(-58°F) TO 71°C (160°F).

ATEX AND IEC SPECIFIC CONDITIONS OF USE: 

ENCLOSURE CONTAINS ALUMINUM. CARE MUST BE 

TAKEN TO AVOID IGNITION HAZARD DUE TO IMPACT 

OR FRICTION.

THIS PRODUCT DOES NOT HAVE ANY FIELD REPLACEABLE 

PARTS. ANY SUBSTITUTION OF COMPONENTS SHALL 

INVALIDATE AGENCY CERTIFICATION(S), AND IMPAIR 

SUITABILITY FOR CLASS I, DIV. 2 LOCATION.

The 117 series pressure and diff erential pressure 

switch utilizes a bellows or diaphragm sensor to 

detect a pressure change. 

The response, at a pre-determined set point, 

actuates a SPDT or DPDT snap-acting switch, 

converting the pressure signal into an electrical 

signal. Control set point may be varied by turning 

the internal adjustment hex (see Adjustment-Part II).

PROOF PRESSURE* LIMITS STATED IN THE 

LITERATURE AND ON NAMEPLATES MUST NEVER 

BE EXCEEDED, EVEN BY SURGES IN THE SYSTEM. 

OCCASIONAL OPERATION OF UNIT UP TO PROOF 

PRESSURE IS ACCEPTABLE (E.G. START-UP, TESTING). 

EXCESSIVE CYCLING AT MAXIMUM PRESSURE 

LIMITS COULD REDUCE SENSOR LIFE. CONTINUOUS 

OPERATION SHOULD NOT EXCEED THE DESIGNATED 

OVER RANGE** OR WORKING PRESSURE RANGE ***.

Proof Pressure - the maximum pressure to which a pressure sensor 

may be occasionally subjected, which causes no permanent damage 

(e.g., start-up, testing). The unit may require re-gapping.

**

 Over Range Pressure - the maximum pressure to which a pressure 

sensor may be continuously subjected without causing damage and 

maintaining set point repeatability.

***

 Working Pressure Range - the pressure range in which two oppos-

ing sensors can be safely operated and still maintain set point provided 

the diff erence in pressure between the low and high sides does not 

exceed the designated adjustable range.

DEVICE MUST NOT BE ALTERED OR MODIFIED AFTER 

SHIPMENT. CONSULT UE IF DEVICE MODIFICATION IS 

NECESSARY. 

Please refer to product datasheet at www.ueonline.com 

for product specifi cations. Date code format on 

nameplate is “YYWW” for year and week.

Part I - Installation

• 

Adjustable Wrench

• 

Screwdriver

• 

Hammer (for alternate wire knockouts)

Mounting

INSTALL DEVICE WHERE SHOCK, VIBRATION AND 

TEMPERATURE FLUCTUATIONS ARE MINIMAL. DO NOT 

INSTALL DEVICE IN AMBIENT TEMPERATURES THAT 

EXCEED PUBLISHED LIMITS ON THE NAMEPLATE.

117 Series

Type H117 (Pressure Switch)
Type H117K (Diff erential Pressure Switch)

Installation and Operation Instructions

Please read all instructional literature carefully and thoroughly before starting. 

Refer to the final page for the Warranty.