INSTALLATION - MOUNTING
UNIMPPT
has been designed for an indoor use.
It incorporates an external temperature sensor which adjusts the load voltage according to the ambient
temperature for an optimal load. It is recommended to instal the device near the battery.
The device has to be mounted on a solid, stable and dry appropriated flat surface.
Standard wiring
Wiring through a wall
To provide the required air circulation needed for cooling the solar charge controller, leave a 5-cm free
space (minimum) all around the device.
Break the 2 caps of the cover
with pliers
Cables exit via the 2
orifices in the cover
Break the cap of
Cables go through a
partition wall
Close the cover by
pushing upwards
Close the cover by
pushing upwards
5cm
5cm
5cm
5cm