It has keypad to programming the instrument. It has Stainless steel
Face plate, which is designed for wall mount Clean Room indication
where you need easy mounting mechanism. This instrument enables
you to measure differential pressure (DP) in the following fields:

The UNITECH “Differential Pressure Indicator : UT-1401” is specially
designed to indicate the Room pressure between two different areas.
The large 4½ digit, 0.4” high LED display is easy to read, even from a
distance. Two alarms can be selected for above or below set point
control, which can help the user to monitor the DP and to take
necessary actions to maintain the room conditions as per the
requirement or application.

INTRODUCTION

z

z

CONTENTS

z

z

HVAC (Heating, ventilation, Air conditioning, cooling)
Pharmacy industry.
Blood stations, pharmacies.
Horticultural and cultivation of plants.

+91 94273 01436

Sales:

www.utplindia.in

Website:

Sure for service with hi-end

versal

nology

Uni

Tech

Sure for service with hi-end

versal

nology

Uni

Tech

E-mail :

[email protected]

Add.-78/1/Z/3, Makarpura GIDC, Makarpura, Vadodara Ph : +91 7046223333

Содержание UT-1401

Страница 1: ...94273 01436 Sales www utplindia in Website Sure for service with hi end versal nology Uni Tech Sure for service with hi end versal nology Uni Tech E mail sales utplindia in Add 78 1 Z 3 Makarpura GID...

Страница 2: ...1 is specially designed to indicate the Room pressure between two different areas The large 4 digit 0 4 high LED display is easy to read even from a distance Two alarms can be selected for above or be...

Страница 3: ...N z z Press to change Set point 1 in Normal Mode and increase selected digit or value in Programming Mode Press to change digit selection or selected value in Programming Mode Press to change Set poin...

Страница 4: ...2206 IP 65 as per IS 2147 2 x 3 4 ET Aluminum alloy Technical data Nos of input Input Indication Range Accuracy Transmitter power supply Comunication Programmable Parameters Other Supply voltage Power...

Страница 5: ...WIRING CONSIDERATION SHIELDED TWISTED PAIR WIRE IS USED FOR ALL ANALOG I P PROCESS SENSORS RTD THERMOCOUPLE DC mV mA VOLT DC LINEAR INPUT AND COMMUNICATION FAILURE TO COMPLY WITH THESE INSTRUCTION MAY...

Страница 6: ...e PROGRAMMING FLOW CHART z z 0000 91 94273 01436 Sales www utplindia in Website Sure for service with hi end versal nology Uni Tech Sure for service with hi end versal nology Uni Tech E mail sales utp...

Страница 7: ...Action TSP2 L oN L oN Change the type by or key One decimal 123 4 0001 Two decimal 12 34 0002 Three decimal 1 234 0003 Active in High H oN Active in Low L oN Active same as above Pressure Unit PASCAL...

Страница 8: ...point Set Point 1 SP1 0300 Increase digit by key decrease by key Activation value for Relay 1 Hys1 0002 Increase digit by key decrease by key Hysteresis 1 Value Difference between Activation and De a...

Страница 9: ...on Range Default Value ofst 0000 Offset to Process Value Scroll the digit by key increase by key This value Increase OR Decrease the Display PV Hys1 0002 Increase digit by key decrease by key Hysteres...

Страница 10: ...ad continuity All LED s and display not light No power to controller Control circuit failure Check power lines connection Check Control Supply Voltages Replace keypads OPEn ERROR MESSAGE AND TROUBLESH...

Страница 11: ...4 SETPOINT 2 40004 READ WRITE DEFAULT COMMUNICATION DETAILS z z BAUD RATE PARITY DATABIT NODE ADDRESS STOP BIT 9600 NONE 8 1 1 91 94273 01436 Sales www utplindia in Website Sure for service with hi en...

Страница 12: ......

Отзывы: