3.2.8. Tag-dead-time
The option of Tag-dead-time allows you to decide the duration to declare a disappeared tag
as dead, which is indicated by a [X] symbol in the inventory, as shown in Fig. 38. Where the
minimum value of this option is suggested to be the dwell time of antennas times the amount
of enabled antenna so that you won’t see tags turn dead at every time the module cycles its
antennas.
Fig. 38. Configuring Tag-dead-time
3.2.9. Anti-stall
The Anti-stall option allows you to decide whether the application disables the failed antenna
automatically while doing the inventory, instead of stopping the process and waiting for your
call, as shown in Fig. 39.
Fig. 39. Configuring Anti-stall
3.3. SmartTune
The “SmartTune” is a part of Configuration that providing you the proper settings for a faster
reading rate, as shown in Fig. 40. The tuning process would take about a minute and is
currently for the single reader environment only.
22