45
5.2.12 GS1-128
Restore Factory Defaults
Restore the Factory Defaults of GS1-128 (default)
Enable/Disable GS1-128
Enable GS1-128 (default)
Disable GS1-128
Message Length
Message length can be set to the maximum value, minimum value. The data between the
maximum and the minimum is valid.
The maximum value and minimum value can be set using Programming command.
Please check the programming command guide for the detail.
GS1-128 max length command: 020B03. The parameter of this command can be set from
min to 80.
GS1-128 min length command: 020B02. The parameter of this command can be set from
0 to max.
Example: Set the Barcode Message length of the minimum value is 10; the maximum
value is 25.
Programming command
Max: 020B0325.
Min: 020B0210.