Unitary Products Group

INSTRUCTIONS FOR DGPT STANDING PILOT MODELS

LIGHTING INSTRUCTIONS

1. STOP! Read the SAFETY IN

Ć

FORMATION.

2. Set the thermostat to the lowest

setting.

3. Turn off all electrical power to the

appliance.

4. Remove the furnace doors.
5. Push in the gas control lever

slightly and move right to “OFF”.

DO NOT FORCE.

6. Wait ten (10) minutes to clear out

any gas. Then smell for gas, in-

cluding near the floor. If you smell

gas, STOP! Follow “C” in the

SAFETY INFORMATION. If you

don’t smell gas, go to the next

step.

7. Open hinged observation door,

the pilot is found at the end of the

pilot shield on the left side of the

burner.

8. Slightly depress the gas control

lever and move it to the left to the

“ON” position and release; then

move it to the “PILOT” position.

9. Move the control lever to “SET”

and hold. Immediately light the pi-

lot with a match (use match hold-

er provided). Continue to hold the

control lever for about one (1)

minute after the pilot is lit. Re-

lease the lever and it will spring

back to the “PILOT”” position. Pi-

lot should remain lit. If it goes out,

repeat steps “5” through “9”

above.

D If the lever does not spring back

when released, stop and immedi-

ately call your service technician

or gas supplier.

D If the pilot will not stay lit after sev-

eral tries, move the gas control le-

ver to “OFF” and call your service

technician or gas supplier.

10. Move the gas control lever to

“ON”.

11. Replace the furnace doors.
12. Turn on all electric power to the

furnace. Set the thermostat to

“HEAT” and/or the desired tem-

perature setting. Set the ON--

OFF--FAN switch to “ON”.

In the event of any flashback or ex

Ć

plosion, immediately shut off the

furnace and call your service tech

Ć

nician.

To Turn off Gas to Appliance

1. Set the thermostat to the lowest

setting.

2. Turn off all electric power to the

appliance if service is to be per-

formed.

3. Remove the furnace doors.
4. Move gas control switch to “OFF”

position. DO NOT FORCE.

5. Replace the furnace doors.

GAS CONTROLCONTROL LEVER

FIGURE 1 -- ROBERT SHAW

GAS VALVE

S

S TT

E

E P

PIILLO

OTTO

ON

NO

OFFFF

P

IL

O

T
P

IL

O

T

A

D

J

A

D

J

11 22

+

+

PRESSURE REGULATING DEVICE

SEQUENCE OF OPERATION

1. On a call for heat, the thermostat

contacts close, supplying 24 VAC

to the gas valve.

2. When the gas valve is energized

it steps open at a reduced flow

and opens fully after approxi-

mately 10 seconds.

3. When the call for heat is satisfied

the thermostat contacts open,

the gas valve shut off gas flow.

THE FURNACE CONTROLS

AND THEIR FUNCTION

1. “ON--OFF--FAN” switch turns

electrical power to the furnace on

and off. The switch must be set in

the “ON” position for the furnace

to operate. To run the blower con-

tinuously without heating, set the

switch to “FAN”.

2. Limit Control -- This furnace is

protected by two (2) high temper-

ature limit switches. The lower

limit switch is an automatic reset

type.

The upper limit switch near left

side of blower is a manual reset

type limit switch (See Figure 2).

If burner does not function, turn

system switch to OFF and push

reset button in center of limit

switch.

Chute to left of blower is hot. Use

care when resetting limit switch

to avoid burns to hand and arm.
If the upper limit switch trips

again soon after resetting, turn

the furnace System Switch to

the OFF position and call your

nearest authorized service tech

Ć

nician.

FIGURE 2 -- FURNACE CONTROLS

BLOWER

SYSTEM

SWITCH

PILOT

ACCESS

DOOR

GAS VALVE

BURNER AIR

SHUTTER

ADJUSTMENT

ROD

AUTOMATIC

RESET LOWER

LIMIT SWITCH

HOT

HOT

UPPER LIMIT

SWITCH

(MANUAL

RESET)

3. Gas Valve -- The gas valve is

100% shut--off type and will fail

safe if for some reason the gas is

turned off or the pilot goes out. It

is also of the modulating or “step--

open” type which means they

open to a “low fire” position and

after a few seconds “step--open”

to “high fire”.

Содержание DGAM

Страница 1: ...ration service or maintenance can cause property damage per sonal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier Never at...

Страница 2: ...ed to operate on only one of these two different gases A small metal tag secured to the fur nace next to the gas valve will specify the type of gas your furnace is equipped to use If the gas is differ...

Страница 3: ...wer to the appliance if service is to be per formed 3 Remove the furnace doors 4 Move gas control switch to OFF position DO NOT FORCE 5 Replace the furnace doors GAS CONTROLCONTROL LEVER FIGURE 1 ROBE...

Страница 4: ...satisfied at which time all burner flame is extin guished Duringthe off cycle no gas is consumed Withthe roomthermostat set below roomtemperature andwith the electrical power andgas supply to the furn...

Страница 5: ...upply fail to shut off shut off the manual gas valve to the furnace and allow blower to run until furnace cools down and blower shuts off before shutting off the electrical supply The furnace gas valv...

Страница 6: ...the tips of the flame will be yellow See Figure 6 5 On Propane gas almost all of the flame will be yellow although some blue should still be present at the base of the flame next to the end of the bu...

Страница 7: ...the supply of gas to the burner in case of malfunc tion For this reason it is never practi cal to assume that the furnace will op erate unattended for a long period of time especially if there is a po...

Страница 8: ...er for assistance in getting the derated orifice installed We hope you follow these instructions and enjoy many years of trouble free service If you have any questions please feel free to contact the...

Отзывы: