Unisto Manta Скачать руководство пользователя страница 28

28

Device functions

Memory block

For  security  reasons  to  prevent  the 

memory  being  filled  by  someone  re-

peatedly  operating  the  locking  handle 

within a short space of time, a memory 

block has been incorporated.

Unisto Manta will not step up data from 

event  00  into  event  01  if  more  than 

three  events  occur  within  5  minutes. 

The third operation within a 5 minute 

period will cause events 01 – 99 to be 

‘frozen’ within the memory.

Event 00 will always correspond to the 

most recent operation.

After 5 minutes of inactivity the mem-

ory block is lifted, enabling new events 

to be stacked in the memory.

If a time and a date setting is attempt-

ed while the Unisto Manta is in ‘Mem-

ory  Block’  the  word  STOP  will  appear. 

Should  this  occur,  wait  5  minutes  for 

the block to be cleared and try again.

Leap years

The  unit  electronics  are  pre-program-

med  and  will  automatically  allow  for 

February 29 every 4 years.

Tamper evident features

The Manta seal is designed and manu-

factured with tamper evident features. 

The  actuator  knob  has  an  integral, 

pre-determined break point. In normal 

use,  it  would  never  be  broken.  A  bro-

ken actuator knob will indicate misuse 

or attempted tampering and should be 

investigated.

Maintenance

1.

 

The  Unisto  Manta  security  seal  is 

practically maintenance-free;

  it  runs  on  pre-installed  batteries 

and is sealed for its service life.

  As  soon  as  the  batteries  run  low, 

the  display  shows  LOW  BATTERY. 

The  unit  should  then  be  replaced 

within 6 weeks.

2.

 

The stainless steel hasp can be re-

placed.  It  should  be  regularly  in-

spected  for  sings  of  wear  or  dam-

age.  Replacements  can  be  ordered 

directly from our sales team. Please 

quote  the  door  type  and  desired 

length of the wire hasp when order-

ing.

Содержание Manta

Страница 1: ...Unisto Manta User guide EP 0016A 500Ac en...

Страница 2: ...2 Manufacturer s address Unisto AG Seestrasse 7 CH 9326 Horn Switzerland Tel 41 71 844 24 24 Fax 41 71 844 25 25 www unisto com...

Страница 3: ...ent 6 Product overview 8 Preparation 11 Positioning and fitting instructions 14 Fitting instructions for various lock types 18 Special applications 19 Added security 20 Usage instructions 22 The event...

Страница 4: ...Package content 1 Standard packaging 2 Unisto Manta Electronic seal 3 Gasket rear 4 Security hasp 5 Mudflap 6 User guide 7 Fixing kit including Allen Key size 2 Unisto Manta User guide Ref AA 39 E 6...

Страница 5: ...5 Package content 1 2 3 4 5...

Страница 6: ...splay for seal number date and time 2 IrDA Interface 3 Select button Back track button 4 Display button 5 Locking handle in open position 6 Locking screw to prevent false openings 7 Reinforcer plate w...

Страница 7: ...7 Product overview Manta rear view 8 Product label 9 fixing points 8 9 9...

Страница 8: ...locking screws on the left and right side of the locking handle Then turn the locking handle either to the left or right Release the socket head screw in the rein forcement plate with the Allen key Re...

Страница 9: ...9 Preparation Manta Hasp Fitting fixed end cont Pull the hasp downward Slide the retaining cover over the inserted hasp Secure the position of the retaining cover with the socket head screw 5 6 7...

Страница 10: ...10 Preparation Manta Preferred opening You may choose from the opening posi tion on either the right or left side Hasp fixed end on the right side Hasp fixed end on the left side 1 2 1 2...

Страница 11: ...s are not impaired in any way Position and fix the Unisto Manta vertical 1 Feed the lose end of the security hasp through the door latch and insert into the open cavity of the Unisto Manta 2 Position...

Страница 12: ...t 1 4 to drill the holes in the doors or shutter Screw the two 6 mm stud bolts into the threaded holes of Unisto Manta by hand HAND TIGHTEN ONLY Slip the rubber gasket over the studs Slip the mudflap...

Страница 13: ...the washers and nuts from the inside of the doors DO NOT OVERTIGHTEN THE NUTS Check how much of the stud bolts are pro truding on the inside of the door and remove excess with a hacksaw Once the exce...

Страница 14: ...s lock types The diagrams shown here are only in tended as a guide door locking mechanisms vary from vehicle to vehicle Container locks Barn door Roller shutter Staple door latches Fix the Unisto Mant...

Страница 15: ...15 Fitting instructions for various lock types Henderson TODCO Type latches...

Страница 16: ...or various lock types Whiting Type Catches Note for Whiting type catches With some types of catch it is necessary to mount the Unisto Manta slightly to the left of the handle see diagram to make sure...

Страница 17: ...Fitting instructions for various lock types Whiting Type Catches Note for handles Whiting 77 Type The Unisto Manta must be mounted in a suitable position where it does not hinder the travel of the han...

Страница 18: ...d into the cavities of the Unisto Manta as de scribed before Alternatively the hasp loop can be used in conjunction with TIR cables The TIR cable terminals must first be flattened slightly with a hamm...

Страница 19: ...19 Added security Padlock 6 mm shank Optional for added security...

Страница 20: ...oor latch and insert into the open cavity of the Unisto Manta Pull down on the hasp and secure by closing the locking handle see diagrams in installa tion instructions Press the DISPLAY button a rando...

Страница 21: ...orded number the shipping documents have been defaced or are illegible the wire hasp of the seal has been damaged or shows signs of having been tampered with In this event sign the documents unsealed...

Страница 22: ...oldest event is 99 Whenever a new event is recorded each event in the stack moves up one place i e data at 00 moves up to become 01 01 moves up to 02 etc Data at 99 is deleted from the memory when a...

Страница 23: ...ton Back track button Display button Press the DISPLAY button Press the SELECT button while the display is illuminated The current seal event num bers will be displayed together Pressing SELECT again...

Страница 24: ...e DISPLAY button Step back to previous events by using the SELECT button This button only steps backwards through the memory If you miss an event you re looking for hold down the SELECT button to fast...

Страница 25: ...re the display switches off Select button Back track button Display button Open the locking handle Then press the DISPLAY button OPEN will be displayed Press and hold down the DISPLAY button Additiona...

Страница 26: ...show with the DAY flashing Set the day with the DISPLAY button as de scribed above Press SELECT again the MONTH will flash Set the correct month as described before For US format program as described...

Страница 27: ...will end as the new time and date will be entered in the memory The change of time and date will be recorded as events as follows Holding down the DISPLAY button fast steps the points 3 6 In case you...

Страница 28: ...block to be cleared and try again Leap years The unit electronics are pre program med and will automatically allow for February 29 every 4 years Tamper evident features The Manta seal is designed and...

Страница 29: ...off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment...

Страница 30: ...er exclusions or requirements have been specified the standard warranty policy will apply 3 Exclusions The warranty does not apply to products where a the serial number is removed or tampered with b t...

Страница 31: ...31 Recommended assembly Recommended cleaning The unit is rated IP 69k Clean only by hand...

Страница 32: ...Unisto Manta User guide EP 0016A 500Ac en Unisto AG CH 9326 Horn www unisto com 23 07 2010...

Отзывы: