Unisen StarTrac E-Spinner Скачать руководство пользователя страница 2

                          620-7900 REV A 

STAR TRAC BY UNISEN CONFIDENTIAL AND PROPRIETARY                              

Page 3 of 8 

4-

 

Disconnect all 4 cables coming out of 

the neck: 

-

 

The Coax cable 

-

 

Ground wire 

-

 

Power cable 

-

 

Data cable 

 

 

 

 

 

 

 

 

5-

 

Now that the display assembly is off, 

set it down on a flat table then unscrew 

the 4 hex screws that hold the neck to 

the display housing using a 3/16 Allen 

key.  Set the neck aside for future use. 

 

 

 

 

 

 

 

 

 

6-

 

Using a Philips-head screw driver, 

remove the 12 screws holding the back 

plastic cover of the display in place.  

 

 

 

 

 

 

 

 

 

Figure 4: Disconnecting display cables

 

Figure 5: Removing plastic cover

 

Figure 6: Removing back cover screws

 

Remove 

screws

 

Remove 

screws

 

Содержание StarTrac E-Spinner

Страница 1: ...a Philips head screw driver remove the two screws holding the bracket to the neck Save the screws for future use 3 Pull on the height adjustment lever of the neck to free it then pull the neck all the...

Страница 2: ...s off set it down on a flat table then unscrew the 4 hex screws that hold the neck to the display housing using a 3 16 Allen key Set the neck aside for future use 6 Using a Philips head screw driver r...

Страница 3: ...the cover in a safe place for future use 8 Using a Philips head screw driver remove the screw that holds the top fan assembly to the chassis 9 Lift top fan assembly to release the heart rate cable fro...

Страница 4: ...19 connector on the board 11 Detach and discard old heart rate board 12 Peal the protective film off of the new heart rate board s adhesive tape Figure 11 Detaching old heart rate board Figure 10 Disc...

Страница 5: ...heart rate board cable through same path of old heart rate cable Tuck cable under top fan assembly Secure top fan assembly using the screw from step 8 Plug new heart rate cable into connector J19 on t...

Страница 6: ...17 Re place and secure the back metal bracket holding the neck to the display housing with 4 screws you saved from step 5 18 Reconnect all 4 cables coming out of the neck The Coax cable Ground wire Po...

Страница 7: ...UNISEN CONFIDENTIAL AND PROPRIETARY Page 8 of 8 19 Insert the display neck assembly back in the bike frame and secure the bracket with the two screws saved from step 2 The heart rate board replacement...

Отзывы: