background image

                         OPERATING MANUAL FOR 

KENTUCKY HOT

 

 

 

 

 

 3

BEFORE FIRST TURN-ON 

 

 3.1

Place of operation

 

1)  The showcase will work correctly: 

- At the workplace with temperature from +16°C to +25 °C  

 
- With ambient humidity max. to 60% RH 

 
 
2)  Do not operate the showcase: 

-  near the cooling nor heating sources 

-  in the place where sunlight can affect operation of the unit 

-  in the place with draught (from air-conditioner or near the entry) 

-  near other objects which could prevent proper ventilation 

 

 3.2

Assembling 

 

Before assembling consider whether the unit is going to be placed on the table or droped in the table. Model Thaya allows the 

installation into the furniture by removing the front bottom panel. It is necessary to keep correct dimensions when you install 

the unit as drop-in. 

 

 

How to drop a showcase in table and what rules need to be met can be found in attachment “Installation into the table” at 

the end of this manual, page 13. If the information is missing or the guide is unclear, contact your supplier. 

 

1)  Showcase should be aligned to the horizontal position by using the adjustable feets on the bottom of the display case. 

Align the showcase by turning the adjustable feet with wrench nr. 24. into horizontal position. After the establishment, 
secure the position of the feets by tightening the nut wrench nr. 17. 

2)  Insert shelf consoles.  

3)  Insert grids to shelves. 

4)  If the model is provided with sliding back doors, insert them.  

 

 3.3

Connection to the electric power

 

The case is designed for single-phase voltage 230V / 50 Hz. The power supply socket must be separately grounded and 

protected by a fuse of 10A. Other devices must not be attached to this separately fused circuit. It is necessary that the 
electrical connections of this showcase is protected and it complies with applicable regulations. 

 
 

 3.4

Before first turn-on 

1)  Visualy check if all packing materials and protective foil were removed. 

2)  Clean the exhibition space, containers and shelves with a slightly damp cloth and a suitable detergent. 

3)  Dry the surface of washed surfaces with a dry cloth. 

4)  The tray located at the rear portion of the case bottom, see chapter 2.3, position 4, should be loaded by approx. 3 

liters of hot (50-60°C) water BEFORE start. The water evaporates during operation and moistens the inner space of 
case (mitigates drying on display). 

 

Check the water level in the tank periodicaly to avoid its complete evaporation. The schowcase can NOT be 
used WITHOUT WATER!

 

 

5)  Heat the interior properly, see chapter 5.2 Turn on. 

 
 

Содержание KENTUCKY HOT GN1

Страница 1: ...Heated top table counter K E N T U C K Y H O T Operating manual...

Страница 2: ...dance intended This manual is intended for all persons who come into contact with the device during the installation operation and maintenance Each of these persons must be thoroughly familiar with it...

Страница 3: ...ust be stored under the following conditions 1 Showcase should be kept in their original packaging in a dry and dark place 2 Do not turn upside down nor to side the showcase Do not place any objects o...

Страница 4: ...permission of the manufacturer is deemed inappropriate purpose For any damage resulting from such an activities the equipment manufacturer is not liable the risk is covered by the user solely Before...

Страница 5: ...OPERATING MANUAL FOR KENTUCKY HOT 3 2 4 Dimensions KENTUCKY HOT GN1 KENTUCKY HOT GN2 KENTUCKY HOT GN3 KENTUCKY HOT GN 4...

Страница 6: ...OPERATING MANUAL FOR KENTUCKY HOT 4 KENTUCKY HOT GN2 High KENTUCKY HOT GN3 High More of technical information can be found in Chapter 9...

Страница 7: ...adjustable feet with wrench nr 24 into horizontal position After the establishment secure the position of the feets by tightening the nut wrench nr 17 2 Insert shelf consoles 3 Insert grids to shelves...

Страница 8: ...sing the showcase If the device is damaged in any way turn it off immediately unplug it from the power supply and contact your supplier Operate the control panel buttons by using fingers exclusively U...

Страница 9: ...nts in the exhibition space up to the highest shelf Heated air is thus injected into all display levels toward the rear doors The air is sucked through grids disposed at sides of the exhibition area a...

Страница 10: ...lay case and raises its temperature The front exhaust and side vents must not be covered by goods or other items Also the space between the containers shelves and the rear sliding door must remain fre...

Страница 11: ...d container water tray Cleaning 6 2 Regularly The power supply cable Control 6 3 Space around and under unit Cleaning 6 1 Daily maintenance Daily clearing of exhibition space from the remnants of the...

Страница 12: ...ustable feets in contact with the floor Are not other devices contiguous or follow too closely of the unit s furniture Does not the unit vibrate too much Is not the showcase in contact with other unwa...

Страница 13: ...tually incorrect repairs as well as defects which have been caused by foreign intervention or force majeure 8 DISPOSAL Once the service life of showcase expired it must be properly disposed of During...

Страница 14: ...N 1 1 20mm Temperature C 30 90 30 90 30 90 30 90 Voltage V Hz 230 50 230 50 230 50 230 50 Power W 1049 2061 2130 2061 Weight kg 43 57 70 78 GN3 High GN4 1S s s 1S s s High Dimensions mm 1080 x 775 x 7...

Страница 15: ...os Name 1 Producer 4 Serial number 2 Contact 5 Technical data 3 Model 6 Production date UNIS COOL s r o Na Ba tici 201 739 01 Star M sto District Fr dek M stek Czech Republic Tel 420 558 655 211 Fax 4...

Отзывы: