U N I Q U E U G P 6 F
4
Clearances
Minimum clearances to combustible materials are:
Top 27”, Sides 2”, Rear 4”
Note: DO NOT install the appliance directly on carpeting. Carpeting must be
removed or protected by a metal or wood panel beneath the appliance, which
extends at least the full width and depth of the appliance.
Keep appliance area clear and free from combustible materials, gasoline and other
liquids with flammable vapors.
W
ARNING
–
D
O NOT USE FLAME TO CHECK FOR GAS LEAKS
Gas Connection
Hook-up to the gas supply line: 3/8” SAE (UNF 5/8” - 18) male flare connection. A
backup wrench must be used when tightening gas supply fitting. All completed
connections should be checked for leaks with a non-corrosive leak detector and/or soap
and water for a bubble check.
The gas supply system must incorporate a pressure regulator to maintain a supply
pressure of not more than 12” water column and no less than 11” water column. (Max
setting)