U N I Q U E U G P 1 3
5
connections should be checked for leaks with a non-corrosive leak detector and/or soap
and water for a bubble check.
WARNING
–
D
O NOT USE FLAME TO CHECK FOR GAS LEAKS
The gas supply system must incorporate a pressure regulator to maintain a supply
pressure of not more than 12” water column and no less than 11” water column. (Max
setting)
Make sure the refrigerator and any other high BTU appliances on your line are turned on
when checking the gas pressure. The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during any pressure testing of that
system at pressures in excess of ½” psig.
In case detailed instructions on the installation and connection of the gas supply are
required, contact your dealer or distributor.
Leveling
Ensure the fridge is level by using a 2ft level; this is accomplished by adjusting the feet at
the front, underneath the fridge.