38
The flames have
suddenly gone
out
There is a power
failure - can I still
use the cooktop
burners?
PROBLEM
Burner flame goes
out at low setting
A draft or spill has
extinguished the
flame.
Power outage in
your area.
POSSIBLE CAUSES
Low gas pressure.
Air intake holes
around burners are
obstructed.
• No action required. The
burner will detect this and
automatically re-light.
However if there has been
a large spill, we recommend
turning the burners off and
cleaning the burners and
sump area. See “Care and
Cleaning” for instructions.
• The cooktop burners can still
be used. To light them:
1.) Holding a lit match to the
flame spreader, push in on
the control knob and turn
counterclockwise to LIGHT.
2.) When the flame is
burning all the way around
the burner, you may adjust
the heat.
If the flame is blown out
during a power failure, turn
the knob immediately to
OFF, as the burner will not
automatically re-light and
gas may escape.
POSSIBLE SOLUTION
• Contact gas company.
• Remove obstruction from air
intake holes.
TROUBLESHOOTING continued
!
CAUTION
There is a power
failure - can I still
use the oven?
Power outage in
your area.
•The oven cannot be used until
power is restored.
Содержание elite UGP-36E6 ON1
Страница 1: ...PROFESSIONAL GAS RANGE OWNER S GUIDE UGP 36E6 ON1 MAR18V1 ...
Страница 14: ...14 INSTALLATION INSTRUCTIONS 36 range dimensions clearances ...
Страница 21: ...21 COOKTOP USE 36 range 15 000 BTU 12 000 BTU 18 000 BTU A C A B B B A B C ...
Страница 41: ...41 UGG 36E6 ON1 WIRING DIAGRAM ...
Страница 47: ... 2018 Unique Gas Products Ltd 2245 Wyecroft Road 5 Oakville Ontario Canada L6L 5L7 www uniqueoffgrid com ...