50
V
á
lv
ula d
e Gas
1. Function
• Valve gas AS supplies or blocks off fuel gas.
• 2 valves are horizontally connected to safely block off gas leakage.
• Each valve is solenoid value. Gas passed through this valve is injected after
being stabilized to the prescribed output pressure in regulator.
• Therefore, even if input pressure of supplied gas changes, the prescribed
amount of gas is stably supplied.
2. Specification
※
power input - rectified 120Vdc
3. Checking method of mal-function
• To check or replace valve gas AS, gas pipe must be locked in advance for safety.
• At room temperature, resistance between two terminals of each valve is 2.4~2.7 k
Ω
.
• Part is defective if resistance between terminal measured after separating cables connected to valve
gas AS is 2.0
Ω
or less or 3.0 k
Ω
or more.
4. Procedure of replacement
1
Remove plate top.
2
Remove panel F ass'y.
3
Remove cabinet front ass'y.
4
Remove frame upper.
5
Remove drum ass'y.
6
Remove 2 screws fixing pipe AS in position.
7
Remove 4 screws fixing pipe AS on to guide bunner.
8
Separate the connected cable and unfasten 1 screw to separate parts.
9
Assemble part in reverse order of the above procedures..
Part Code : 3615417200, -7300
Part Code
Type Name
Electric Rating
Input pressure
Output pressure
LPG
3615417200
DEGB-1011
120V 60Hz 0.07A
2.0~3.5 kPa
2.24 kPa
LNG
3615417300
1.0~3.5 kPa
0.87 kPa
6
Pipe AS
7
Guide Buner
합본 svc manual 2008.5.6 6:24 PM 페이지64
Содержание KUD-WG33S
Страница 1: ...JUL 2008 Service Manual Model KUD WG33S Gas Dryer ...
Страница 8: ...1 DRYER CBINET ASS Y PartsListbyAss y 7 ...
Страница 35: ...33 2 DIAGRAMA SECADORA DE GAS ...
Страница 43: ...42 7 Remove wires and 2 screws that fix the switch 8 Assemble the parts in reverse order Belt Switch ...
Страница 58: ...57 BLOCK DE TERMINALES 1 Remove cover terminal 2 Remove 3 screws sólo secadora eléctrica ...
Страница 63: ...4 Switch de Puerta Presione los seguros y empuje hacia el frente ...