background image

U G P - 3 0 E   –   C T 2  

 

14

piped connection. Never reuse an old connector when installing a new rangetop. If 
the hard piping method is used, you must carefully align the pipe. 
  
To prevent gas leaks, use pipe joint compound resistant to NG gases on all male 
external pipe threads. 
 

1.

 

In an easily accessible location, install a service manual gas shut off valve. Be 
sure everyone operating the rangetop knows where and how to shut off the 
gas supply to the cook top. 

 

2.

 

Use a flexible gas line to connect to the 1/2” fitting, located on the bottom 
right hand corner underneath the rangetop. 

 

3.

 

When all connections have been made, be sure all rangetop controls are in 
the off position and turn on the main gas supply valve. Check for gas leaks 

by using a 75% water, 25% dish washing soap solution. If a gas leak is 
present, shut off gas immediately, tighten all connections, and retest for 
leaks. 

!

4.

 

Any opening in the wall behind the appliance and in the floor under the 
appliance shall be sealed. 

 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 

Содержание UGP-30E CT2

Страница 1: ...w rangetop install it or have them recommend a qualified installer Installation must conform with local codes In the absence of local codes the installation must conform with the National Fuel Gas Cod...

Страница 2: ...ply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig CLEARANCES All units must...

Страница 3: ...nty Any expenses incurred due to such situations will not be paid by the manufacturer of the appliance Note Based on 24 61 cm deep cabinet x This rangetop may be installed directly adjacent to existin...

Страница 4: ...inets above the rangetop must be a minimum of 42 106 7 cm above the rangetop cooking surface for the full width of the rangetop This minimum height requirement does not apply if a rangetop hood is ins...

Страница 5: ...existing 36 91 4 cm high base cabinets x The rangetop CANNOT be installed directly adjacent to sidewalls tall cabinets tall appliances or other side vertical surfaces above 36 91 4 cm Note There must...

Страница 6: ...is 6 15 2 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop x Wall cabinets above the rangetop must be a minimum of 42 106 7 cm above the rangetop cooking surface for the full...

Страница 7: ...U G P 3 0 E C T 2 12 Make the countertop cut out following the dimensions given in the illustration above Base below rangetop must be of a non combustible material...

Страница 8: ...ressure of natural gas supplied to the regulator should be between 4 and 5 of water column For LP gas the pressure supplied must be between 10 and 12 of water column When checking for correct operatio...

Страница 9: ...top knows where and how to shut off the gas supply to the cook top 2 Use a flexible gas line to connect to the 1 2 fitting located on the bottom right hand corner underneath the rangetop 3 When all co...