background image

 
 

 

 

6

 

 

 

 

3.2 Mode Switches Selection  

Designation:

NS-Functional select 
DS-Shutter speed select 

 

 

 

 

 

NR- RS-232C communication Enable 

RI-  Rear switch control Enable 
NP- Reserved for custom options 
PS- Reserved for custom options 

NM-Normal mode 

AM-Asynchronous mode 
 
Timing details of the mode switches are shown in section 6. 

 

                       

 

3.3 Shutter Speed Dial Switch 
 

Shutter speed dial switch is located on the rear panel and there are 16 different positions.  To 

select camera gain, reference, or to save a user page, set NS/DS switch to NS position.  To adjust 
shutter speed, set NS/DS to DS position.  For normal shutter speed, make sure to set NM/AM mode 
to NM location.  For asynchronous capture, set NM/AM mode to AM location.

     

 

 

Position No. 

Functional Select 

(NS) 

Shutter Speed Select (DS) 

Normal Speed 

Double Speed (2x2 binning) 

Shutter 

Speed (sec) 

(NM Mode) 

Asynchronous 

Capture (sec) 

(AM Mode) 

 

Shutter 

Speed (sec) 

(NM Mode) 

Asynchronous 

Capture (sec) 

(AM Mode) 

 

Normal 

1/16 (Off) 

No shutter 

1/32 

No shutter 

Gain Adjustment 

1/50 

1/500 

1/50 

1/500 

Reference Adjustment 

1/100 

1/1,000 

1/100 

1/1,000 

Factory Page 

1/200 

1/1,500 

1/200 

1/1,500 

User Page 1 

1/400 

1/2,000 

1/400 

1/2,000 

User Page 2 

1/500 

1/3,000 

1/500 

1/3,000 

User Page 3 

1/1,000 

1/4,000 

1/1,000 

1/4,000 

User Page 4 

1/2,000 

1/5,000 

1/2,000 

1/5,000 

Normal/Double Speed 

1/3,000 

1/6,000 

1/3,000 

1/6,000 

Reserved 

1/5,000 

1/6,500 

1/5,000 

1/6,500 

Reserved 

1/6,500 

1/8,000 

1/6,500 

1/8,000 

Reserved 

1/8,000 

1/10,000 

1/8,000 

1/10,000 

Reserved 

1/10,000 

1/15,000 

1/10,000 

1/15,000 

Reserved  

1/13,000 

1/20,000 

1/13,000 

1/20,000 

Reserved 

1/20,000 

1/40,000 

1/20,000 

1/40,000 

Reserved 

1/40,000 

Pulse Width 

Control 

1/40,000 

Pulse Width 

Control 

 

 
 

         Figure 4. Shutter Speed Dial Switch

 

 

 

Figure 3. Mode switches

 

Содержание UP-2000CL

Страница 1: ...UP 2000CL Digital CCD Camera User s Manual 091 2000 V 1 4 02 03 17 ...

Страница 2: ...2 Precautions 2 Limited Warranty 2 1 Introduction 3 2 Camera Setup 5 3 Camera Functions 5 4 RS 232C Communication Control 9 5 Digital Interface Timing 10 6 Camera Functional Timing 11 7 Camera Accessories 13 8 Technical Support 13 ...

Страница 3: ...ts Limited Warranty UNIQ warrants to the original customer to be free from defects in material and workmanship for two full years from the date of original purchase This warranty covers failures or damages due to defects in material or workmanship which occur during normal use It does not cover damages or failures which result from shipment mishandling abuse misuse or modification A Return Materia...

Страница 4: ... 1 2 Progressive Scan CCD Imager 1620 x 1236 active pixels 16 Hz frame rate 2 x 2 810 x 618 Binning at 32 FPS 10 bit Camera Link output Analog output Full frame shutter 1 16 1 40 000 sec 58 dB Asynchronous reset at full frame shutter 40 MHz data clock RS232C interface control C mount lens 1 3 Applications UP 2000CL applications include machine vision automated inspection motion capture and analysi...

Страница 5: ...PS for 2x2 binning Sync HD 19 979 KHz VD 16 009 Hz Digital Video Output Camera Link format Analog Video Output 1 V p p 75ohm BNC or 12 pin Hirose S N Ratio 58 dB Min Illumination 0 1 lux Gain MGC Gamma 1 0 Electronic Shutter 1 16 1 40 000 selectable Lens Mount C Mount Operating Temperature 10 C 55 C Power Requirement 12V DC 300mA 3 6 W Dimension 50mm x 39mm x 83mm Ext Sync Internal External Auto S...

Страница 6: ...3 1 12 Pin Connector The 12 pin Hirose connector is located on the rear panel of the camera All ground signals on pin 1 3 5 and 8 are common grounds 12 V DC input is recommended on pin 2 but this camera should withstand 12 V 1V input voltage Make sure to set the NM AM switch to NM position for external HD and VD locking Figure 2 below shows a top view of the 12 pin Hirose connector Pin No UP 2000C...

Страница 7: ...eed Double Speed 2x2 binning Shutter Speed sec NM Mode Asynchronous Capture sec AM Mode Shutter Speed sec NM Mode Asynchronous Capture sec AM Mode 0 Normal 1 16 Off No shutter 1 32 No shutter 1 Gain Adjustment 1 50 1 500 1 50 1 500 2 Reference Adjustment 1 100 1 1 000 1 100 1 1 000 3 Factory Page 1 200 1 1 500 1 200 1 1 500 4 User Page 1 1 400 1 2 000 1 400 1 2 000 5 User Page 2 1 500 1 3 000 1 50...

Страница 8: ...ttings can be saved into four different user pages Once the user page is saved and set between shutter speeds 4 and 7 it will be activated as long as the camera is powered ON User Page works in both rear plate control and RS232C communication selections 3 5 Gain Control AGC MGC Note This gain potentiometer only applies to cameras without Up Down switch on rear plate Manual gain control MGC MGC is ...

Страница 9: ...3 Video LEN and FEN data output 7 20 SerTC SerTC Rx Rx Differential pair serial communications from frame grabber 8 21 SerTFG SerTFG Tx Tx Differential pair serial communications to frame grabber 9 22 CC1 CC1 HD HD Camera Control 1 CC1 Horizontal signal input 10 23 CC2 CC2 VINIT VD VINIT VD Camera Control 2 CC2 Vertical signal or asynchronous reset input 11 24 CC3 CC3 Reserved Reserved for custom ...

Страница 10: ...actor of 1 If a number is entered then number will be added to stored gain gd Gain decrease Hexadecimals 000 3ff Same as gi above except it will be decreased gn Gain number Hexadecimals 000 3ff Refer to the gain curves below for details Only one curve applies to each camera depending on camera model contact UNIQ for further details bi Reference increase Hexadecimals 000 3ff If no number entered re...

Страница 11: ... 1 Pixel Clock 5 2 Line Enable 5 3 Frame Enable 5 4 Pixel Clock for 2 x 2 Binning 5 5 Line Enable for 2 x 2 Binning 5 6 Frame Enable for 2 x 2 Binning Note 1 1 N 25 nsec 50 nsec for 2 x 2 binning 2 1 H 2000 N 1000 N for 2 x 2 binning ...

Страница 12: ...er speed position 0 16 fps 6 2 Free Run shutter speed position from 1 to F 6 3 Asynchronous Capture shutter speed position 0 6 4 Asynchronous Capture shutter speed position from 1 to E 6 5 Asynchronous Capture with Pulse Width Control shutter speed F ...

Страница 13: ...gure 10 External Synchronization and Gen lock Timing 6 7 Integration via 12 pin Hirose connector ONLY The UP 2000CL camera can be integrated up to 2 seconds without severe noise or dark current effect To start integration pin 11 same as pin 27 of 40 pin digital connector of the 12 pin connector must be connected to GND or 0V The integrated video will be shifted out following the next vertical driv...

Страница 14: ...mera There are a variety of C mount lenses in the market that works with UP 2000CL camera Make sure the quality and specification of the lens match the camera s application Some of the most popular lenses in the market such as Cosmicar Fujinon Rodenstock and Schneider are recommended 7 3 Camera Link Cable Camera Link cable can be purchased from 3M Mouser Digi Key and frame grabber vendors 8 Techni...

Отзывы: