44
7
Appendices
44
Appendices
Chapter
7
7-1.
List of setting values
* Default value
Factory default value
* Protection
◎
: System setting protection
●
: Calibration setting protection
* NOVRAM
◎
: Saving on NOVRAM
* Reference
Reference page number for each item description
■
System setting (settings tab)
■
Calibration setting (calibration tab)
Item
number
Setting value name
Setting value range
Default
value
Protection
NOV
RAM
Reference
1
Moving average filter (torque)
0 (OFF), 2 to 300 [times]
30
◎
◎
2
Digital low-pass filter
3, 30, 300, Off [Hz]
300
◎
◎
3
Moving average filter
(rotation speed)
0 (OFF), 2 to 300 [times]
30
◎
◎
Item
number
Setting value name
Setting value range
Default
value
Protection
NOV
RAM
Reference
1
Calibration function selection1
Unit (torque)
mNm, Ncm, Nm, kNm,
kgm (kgfm), kgcm (kgfcm),
gcm (gfcm)
Nm
●
◎
2
Calibration function selection1
Min. scale division (torque)
1, 2, 5, 10, 20, 50, 100
1
●
◎
3
Calibration function selection2
Pulse rate (rotation speed)
1 pulse, 4 pulses
4 pulses
●
◎
4
Calibration function selection2
Min. scale division
(rotation speed)
1, 2, 5, 10
1
●
◎
5
Rotation stop settings
Minimum input rotation speed
Pulse rate: 4 pulses
15rpm, 10rpm, 5rpm,
3rpm, 2rpm
Pulse rate: 1 pulse
60rpm, 40rpm, 20rpm,
12rpm, 8rpm
15rpm
●
◎
6
Rotation stop settings
Rotation stop mode
OFF, 2 times, 4 times, 8 times
OFF
●
◎
7
Calibration function selection2
Unit (power)
mW, W, kW, PS, HP
W
●
◎
8
Calibration function selection2
Decimal place (power)
99999, 9999.9,
999.99, 99.999
99999
●
◎
9
Calibration function selection2
Min. scale division (power)
1, 2, 5, 10
1
●
◎
7
Appendices
Содержание TM201
Страница 1: ...TM201 01DEC2015REV 3 01 TORQUE MONITOR OPERATION MANUAL ...
Страница 9: ...Contents VIII Contents VIII M E M O ...
Страница 58: ......