6.SETTING AND ADJUSTMENT OF READING
86
6-9. States Ascertain
6-9-1. Belt speed over asc.
Use this parameter to stop the belt if it has moved too fast over a period longer than
specified by this parameter. If the belt travels faster for a period longer than specified
by BELT SPEED OVER ASC., it is forced to come to a halt, indicating “Sequence
error 5”.
* Setting this parameter to 999 sec disables auto stop function. Over-scale alarm is
displayed.
* Setting this parameter to 0 sec disables auto stop function. Over-scale alarm is not
displayed.
Operation
6-9-2. Weight density over asc.
Use this parameter to stop the system if has carried excess weight over a period longer
than specified by this parameter. If the “weight density over” condition continued
longer than the value specified by WEIGHT DENSITY OVER ASC., the system is
forced to come to a halt, indicating “Sequence error 6”.
* Setting this parameter to 999 sec disables auto stop function. Over-scale alarm is
displayed.
* Setting this parameter to 0 sec disables auto stop function. Over-scale alarm is not
displayed.
Operation
MODE
STATES ASCERTAIN
BELT SPEED OVER ASC.
→
→
Range: 0 – 999 sec (3 digits, no decimal place)
Range: 0 – 999 sec (3 digits, no decimal place)
MODE
STATES ASCERTAIN
WEIGHT DENSITY OVER ASC.
→
→