1.APPEARANCE DESCRIPTION
2
1-2. Status LED
Status LEDs display the current operating status of the unit. The following table
summaries their names and meanings.
LED
Name
State
Description
RUN
(
Green
)
Operation status
ON
Normal operation
OFF Data exchange with CPU has been aborted
ERC
(
Red
)
Error detected
by the unit
ON
Error occurred in F159
OFF Normal operation
ERH
(
Red
)
CPU error
ON
Error occurred during data exchange with CPU
OFF Normal operation
WERR
(
Red
)
Weight error
ON
One or more of the following alarms are in
place:
±
LOAD, OFL1, OFL2, OFL3, ZALM
OFF Normal operation
OUT1
(
Orange
)
OUT1 output
ON
OUT1 =ON
OFF OUT1 = OFF
OUT2
(
Orange
)
OUT2 output
ON
OUT2 = ON
OFF OUT2 = OFF