11.SPECIFICATIONS
28
11-3. Setting
High performance I/O unit No.
Decimal 2-digit rotary switch (unit No. 0 to 95)
Calibration value
・
set value setting method
Made from the CPU unit via the data memory (DM) area
defined for the F130.
Calibration value
Stored in NOV RAM (non-volatile RAM)
Set value
Measurement starts with the set values (DM area) written from the
CPU unit after power-on. (Not stored on the F130 side)
11-4. Terminal Block Layout
Detachable terminal block (M3 screw)
* Never connect anything to the RSV terminals.
11-5. General Specifications
Internal consumption current
DC5V, Approx. 0.46A
(At excitation voltage DC10V,
single 350Ω
sensor)
Operating conditions
Operation temperature:
0
℃
to +55
℃
Accuracy compensation applicable temperature:
0
℃
to +40
℃
Storage temperature:
-20
℃
to +75
℃
Humidity:
90%RH or less (non-condensing)
Dimensions
31(W)
×90
(H)
×65
(D) mm (protrusions excluded)
Weight
Approx. 160g
SHIELD
B1
+SIG
B2
-SIG
B3
+EXC
B4
-EXC
B5
RSV
B6
RSV
B7
RSV
B8
RSV
B9
A1
RSV
A2
RSV
A3
RSV
A4
RSV
A5
RSV
A6
RSV
A7
RSV
A8
RSV
A9
RSV