![Unipower INV2500-HS Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/unipower/inv2500-hs/inv2500-hs_operating-manual_3901641008.webp)
5
INV2500-HS & INV5000-HS SERIES
OPERATING MANUAL
6.4
Always save the packing materials for later use in shipping the unit. Never
ship the inverter without proper packing.
7.0
DESCRIPTION OF OPERATION
7.1
The INV2500-HS modules employ MOSFET and IGBT power semiconductor
switches with advanced, high-frequency, pulse modulation techniques to
produce a low-distortion, 50 or 60Hz sine wave output with 90% efficiency
and 7VA per cubic inch power density. A synchronization circuit lets two or
more inverter modules operate in parallel with their outputs in phase-synchro-
nization and current shared.
7.2
The INV5000-HS-230 inverter system consists of two INV2500-HSs oper-
ated in series for a 230VAC output at 5,000 volt-amperes (22A). The series
connection of the units is made internally in the shelf. Each of the two inverter
modules has its own input and output breakers, indicator LEDs and Form C
relay contacts. The two inverter modules in the INV5000-HS are different in
that their outputs are 180
o
out of phase with each other.
7.3
Two INV2500-HS inverter modules in an INVR2U-HS shelf are connected in
parallel in the shelf and become an inverter system with a 115VAC output at
5,000 volt-amperes (44A).
7.4
For the purpose of this manual, the INV5000-HS-230 and two INV2500-
HS modules in an INVR2U-HS shelf are both 5,000 VA inverter systems
and will be referred to as an INV5000-HS where the generic meaning is
conveyed. While the two different shelves are identical in size and appear-
ance, they differ in their internal module connection (series or parallel).
8.0
FRONT AND BACK PANEL DESCRIPTIONS
8.1
Figure 2 shows the front and back of an INV2500-HS inverter module. On
the left side of the front panel of the INV2500-HS is the input circuit breaker.
To the right are the two cooling fans and the output circuit breaker. Above the
output breaker from the top are the green LED indicators for Input OK, Sync
OK and Output OK.
8.2
On the INV2500-HS back panel on the right side is the hot-swap connector
which contains all power and signal connections.
8.3
Figure 3 shows the front and back of an INV5000-HS. Each front half (side A