background image

Page 8

DPAC1U SERIES

OPERATING MANUAL

P O W E R I N G   T E C H N O L O G Y

Manual No. dpac1u-5

dpac-man-Rev5-0119.indd

option, may repair or replace the non-conforming product or issue credit, provided the
manufacturer’s inspection establishes the existence of a defect.  To exercise this remedy, the
buyer must contact the manufacturer’s Customer Service Department to obtain a Return Material
Authorization number and shipping instructions.  Products returned without prior authorization
will be returned to buyer.  All products returned for repair must be shipped freight prepaid to
UNIPOWER.  If the buyer fails to fully comply with the foregoing, the buyer agrees that no other
remedy (including, but not limited to, incidental or consequential damages for lost profits, lost
sales, injury to person or property or any other incidental or consequential losses) shall be
available to the buyer.

6.0

FUNCTIONAL DIAGRAM

A simplified schematic diagram of the AC Distribution Panels is shown in Figure 3.
The diagram represents the A or B side of the panel. The input handles one or two
inverters with up to 25A each. The output goes to as many as four AC circuits with a
circuit breaker on each. The A and B sides can be in common (standard) or isolated
(option). This is determined at the time of ordering.

7.0

SPECIFICATIONS

INPUT / OUTPUT

Configuration ..........................................Single (A) or Dual (A & B) Sections
Current Capacity .............................................. 50A Per Section, 100A Total
No. of Circuit Breakers ............................... 2 to 4 Per Section, Up to 8 Total
Breaker Capacity, Option T ........................................................... 5A to 30A

Option C ........................................................... 5A to 15A

Voltage .............................................................................. 120VAC Nominal

SAFETY STANDARDS

...................... UL1950, CSA22.2 No.950, EN60950

ENVIRONMENTAL

Operating Temp. Range .......................................................... 0°C to +50°C
Storage Temp. Range ......................................................... -40°C to + 85°C
Humidity ......................................................... 0% to 95%, Non-Condensing

PHYSICAL SPECIFICATIONS

Case Material ....................................................................................... Steel
Finish .............................................................................. Powder Coat Gray
Dimensions, Inches (mm) ................................. 1.75 H x 17.13 W x 11.00 D

(44.5 x 435 x 279)

Weight ......................................................................... 10.25 lbs. (4.65 kg.)
Rack Mounting Width .......................................................... 19 or 23 Inches

CONNECTIONS

Input/Output Connections .......................................... Barrier Terminal Strips

Positronics/NEMA 5-15R Receptacle

Chassis Ground Connection .................................................. No. 8-32 Stud

Содержание DPAC1U Series

Страница 1: ...com Manual No DPAC1U 5 2019 UNIPOWER LLC All Rights Reserved dpac man rev5 0119 indd UNIPOWER LLC 3900 Coral Ridge Drive Coral Springs Florida 33065 USA sales unipowerco com NORTH AMERICA CALA CALL 1...

Страница 2: ...man Rev5 0119 indd Contents 1 0 INTRODUCTION 4 2 0 FEATURES OPTIONS 6 3 0 FRONT REAR PANEL DESCRIPTIONS 7 4 0 SAFETY WARNINGS 7 5 0 WARRANTY 7 6 0 FUNCTIONAL DIAGRAM 8 7 0 SPECIFICATIONS 8 8 0 BACK PA...

Страница 3: ...No dpac1u 5 dpac man Rev5 0119 indd FIGURES Figure 1 DPAC1U AC Power Distribution Panel 5 Figure 2 Front and Rear Views of DPAC1U 5 Figure 3 Simplified Diagram of DPAC1U A or B Side 9 Figure 4 Inverte...

Страница 4: ...is only 1 75 inches 1 rack space high to minimize rack space and can be mounted in either a 19 or 23 inch relay rack with corresponding brackets It can be mounted from the front of the rack with offs...

Страница 5: ...ONT VIEW REAR VIEWS 17 13 435 1 5 2 6 1 5 2 6 1 75 44 5 T OPTION C OPTION INPUT 1 LOAD 1 LOAD 5 INPUT 2 LOAD 2 GND L N G LOAD 1 LOAD 5 INPUT 1 LOAD 2 LOAD 6 INPUT 2 B A A B 1 2 5 6 1 2 5 6 INPUTS INPU...

Страница 6: ...tions A and B the two sections are connected in common parallel In an optional model option I the A and B sections are isolated There are two options for input and output connections The T option prov...

Страница 7: ...use of power systems and are well aware of the hazards involved 4 2 When operating this Distribution Panel the chassis ground terminal must be connected to the system frame ground or other proper saf...

Страница 8: ...simplified schematic diagram of the AC Distribution Panels is shown in Figure 3 The diagram represents the A or B side of the panel The input handles one or two inverters with up to 25A each The outp...

Страница 9: ...o dpac1u 5 dpac man Rev5 0119 indd Figure 3 Simplified Diagram of DPAC1U A or B Side Figure 4 Inverter Connections to DPAC1U a Four Connected to DPAC1U b 2 inverters in Rack 115VAC only Connected to D...

Страница 10: ...el The only exception to this is the version of the DPAC1U which has isolated A and B sections Suffix code I In this case the A and B sides can have different phases since they are not connected in co...

Страница 11: ...Page 11 DPAC1U SERIES OPERATING MANUAL P O W E R I N G T E C H N O L O G Y Manual No dpac1u 5 dpac man Rev5 0119 indd Figure 5 Positronics Connector on C Option of DPAC1U...

Страница 12: ...so save the shipping carton and packing materials as evidence of damage for the freight carrier s inspection UNIPOWER LLC will cooperate fully in case of any shipping damage investigation Always save...

Страница 13: ...source Check the AC output voltage from line to neutral at each set of output terminals loads with a digital AC voltmeter The voltage should be approximately 120VAC 11 4 On the A side set all ciruit...

Отзывы: