Page 5

DPAC1U SERIES

OPERATING MANUAL

P O W E R I N G   T E C H N O L O G Y

Manual No. dpac1u-5

dpac-man-Rev5-0119.indd

Figure 2. Front and Rear Views of DPAC1U

Figure 1. DPAC1U AC Power Distribution Panel

FRONT VIEW

REAR VIEWS

17.13

(435)

1

5

2

6

1

5

2

6

1.75

(44.5)

T OPTION

C OPTION

INPUT 1

LOAD 1

 

LOAD 

5

INPUT 2

LOAD 2

GND

L  N  G

LOAD 1

 

LOAD 

5

INPUT 1

LOAD 2

 

LOAD 

6

INPUT 2

B

A

A

B

1

2

5

6

1

2

5

6

INPUTS

INPUTS

1

2

3

4

S

D

A

O

L

S

D

A

O

L

L  N  G

L  N  G

L  N  G

L  N  G

L  N  G

L  N  G

L  N  G

L  N  G

L  N  G

L  N  G

L  N  G

WALLET SLOT

LOAD 

6

1   2   3

L  N  G

POSITRONICS

CONNECTORS

GND

1   2   3

L  N  G

POSITRONICS

CONNECTORS

NEMA 5-15R

RECEPTACLES

NEMA 5-15R

RECEPTACLES

Figure 2. Front and Rear Views of DPAC1U

Figure 1. DPAC1U AC Power Distribution Panel

FRONT VIEW

REAR VIEWS

17.13

(435)

1

5

2

6

1

5

2

6

1.75

(44.5)

T OPTION

C OPTION

INPUT 1

LOAD 1

 

LOAD 

5

INPUT 2

LOAD 2

GND

L  N  G

LOAD 1

 

LOAD 

5

INPUT 1

LOAD 2

 

LOAD 

6

INPUT 2

B

A

A

B

1

2

5

6

1

2

5

6

INPUTS

INPUTS

1

2

3

4

S

D

A

O

L

S

D

A

O

L

L  N  G

L  N  G

L  N  G

L  N  G

L  N  G

L  N  G

L  N  G

L  N  G

L  N  G

L  N  G

L  N  G

WALLET SLOT

LOAD 

6

1   2   3

L  N  G

POSITRONICS

CONNECTORS

GND

1   2   3

L  N  G

POSITRONICS

CONNECTORS

NEMA 5-15R

RECEPTACLES

NEMA 5-15R

RECEPTACLES

FRONT VIEW

17.13 (435)

REAR VIEWS

1.75

(44.5)

1

5

2

6

1

5

2

6

A

B

INPUT

1

LOAD

1

LOAD

6

L N G

L N G L N G

L N G

L N G L N G

A

B

INPUT

2

LOAD

2

1

2

5

6

1

2

5

6

GND

LOADS

LOADS

B INPUTS

A INPUTS

GND

1

2

1

2

POSITRONICS

CONNECTORS

LOAD

5

LOAD

1

LOAD

2

INPUT

2

L N G  L N G

L N G

L N G  L N G

L N G

LOAD

5

LOAD

6

INPUT

1

5

6

3

4

1

2

OFF

O

ON

I

15

OFF

O

ON

I

15

OFF

O

ON

I

15

OFF

O

ON

I

15

5

6

3

4

1

2

OFF

O

ON

I

15

OFF

O

ON

I

15

OFF

O

ON

I

15

OFF

O

ON

I

15

1   2   3   4   5   6   7   8   9  10

1   2   3   4   5   6   7   8   9  10

Содержание DPAC1U Series

Страница 1: ...com Manual No DPAC1U 5 2019 UNIPOWER LLC All Rights Reserved dpac man rev5 0119 indd UNIPOWER LLC 3900 Coral Ridge Drive Coral Springs Florida 33065 USA sales unipowerco com NORTH AMERICA CALA CALL 1...

Страница 2: ...man Rev5 0119 indd Contents 1 0 INTRODUCTION 4 2 0 FEATURES OPTIONS 6 3 0 FRONT REAR PANEL DESCRIPTIONS 7 4 0 SAFETY WARNINGS 7 5 0 WARRANTY 7 6 0 FUNCTIONAL DIAGRAM 8 7 0 SPECIFICATIONS 8 8 0 BACK PA...

Страница 3: ...No dpac1u 5 dpac man Rev5 0119 indd FIGURES Figure 1 DPAC1U AC Power Distribution Panel 5 Figure 2 Front and Rear Views of DPAC1U 5 Figure 3 Simplified Diagram of DPAC1U A or B Side 9 Figure 4 Inverte...

Страница 4: ...is only 1 75 inches 1 rack space high to minimize rack space and can be mounted in either a 19 or 23 inch relay rack with corresponding brackets It can be mounted from the front of the rack with offs...

Страница 5: ...ONT VIEW REAR VIEWS 17 13 435 1 5 2 6 1 5 2 6 1 75 44 5 T OPTION C OPTION INPUT 1 LOAD 1 LOAD 5 INPUT 2 LOAD 2 GND L N G LOAD 1 LOAD 5 INPUT 1 LOAD 2 LOAD 6 INPUT 2 B A A B 1 2 5 6 1 2 5 6 INPUTS INPU...

Страница 6: ...tions A and B the two sections are connected in common parallel In an optional model option I the A and B sections are isolated There are two options for input and output connections The T option prov...

Страница 7: ...use of power systems and are well aware of the hazards involved 4 2 When operating this Distribution Panel the chassis ground terminal must be connected to the system frame ground or other proper saf...

Страница 8: ...simplified schematic diagram of the AC Distribution Panels is shown in Figure 3 The diagram represents the A or B side of the panel The input handles one or two inverters with up to 25A each The outp...

Страница 9: ...o dpac1u 5 dpac man Rev5 0119 indd Figure 3 Simplified Diagram of DPAC1U A or B Side Figure 4 Inverter Connections to DPAC1U a Four Connected to DPAC1U b 2 inverters in Rack 115VAC only Connected to D...

Страница 10: ...el The only exception to this is the version of the DPAC1U which has isolated A and B sections Suffix code I In this case the A and B sides can have different phases since they are not connected in co...

Страница 11: ...Page 11 DPAC1U SERIES OPERATING MANUAL P O W E R I N G T E C H N O L O G Y Manual No dpac1u 5 dpac man Rev5 0119 indd Figure 5 Positronics Connector on C Option of DPAC1U...

Страница 12: ...so save the shipping carton and packing materials as evidence of damage for the freight carrier s inspection UNIPOWER LLC will cooperate fully in case of any shipping damage investigation Always save...

Страница 13: ...source Check the AC output voltage from line to neutral at each set of output terminals loads with a digital AC voltmeter The voltage should be approximately 120VAC 11 4 On the A side set all ciruit...

Отзывы: