AC Turn-On Procedure
After making all connections to the power supply and making sure they are tight, follow this procedure to
energize the equipment:
1.
Place the “Float-Equalize” rocker switch in the “Float” position.
2.
Close the DC circuit breaker. The battery will charge the filter capacitors connected across the DC
output. The DC voltmeter on the front panel should read the battery voltage.
*Note: In-rush current may trip the breaker. If so, reclose.
3.
Close the AC circuit breaker. The output current will build up gradually due to the “walk-in” or
“soft-start” characteristic of the equipment.
If the equipment is used without a battery, the capacitor will become charged when the AC breaker is closed. In
this instance, both the current and voltage will build up gradually, provided some load is connected.
2.1.2
Alternate AC Turn-On Procedure
After making all connections to the power supply and checking them for tightness use the following procedure to
energize the equipment:
1.
Place the float/equalize rocker switch in the float position and set the local/remote switch to local.
2.
Close the ac circuit breaker. Wait several seconds for the dc voltage to reach its set point.
3.
Close the dc circuit breaker. If inrush of current trips the dc breaker, reset it and proceed. Refer to
drawings in back of manual for location of switches.
2.1.3
AC Turn-Off Procedure
In order to de-energize or turn off the power supply, the following steps need to be followed in the indicated
order:
1.
Open the AC circuit breaker.
2.
Open the DC circuit breaker.
2.1.4
Float/Equalize Settings
The float and equalize voltage levels are factory set. These settings are indicated by a red card attached on the
inside front of the equipment. However, you may wish to change the settings to fit your particular application.
The table 2-1 shows typical float and equalize voltages on a per cell basis for different types of batteries.
TABLE 2-1: TYPICAL FLOAT/EQUALIZE VOLTAGES
CELL VOLTAGE
BATTERY TYPE
FLOAT
EQUALIZE
LEAD ANTIMONY (1.210 Specific gravity)
LEAD CALCIUM (1.210 Specific gravity)
NICKEL CADMIUM
NICKEL IRON
LEAD-ACID, VALVE-
REGULATED (SEALED)
(1.300 Specified gravity)
(1.290 Specified gravity)
(1.245 Specified gravity
2.15 – 2.17
2.17 – 2.25
1.43
1.50 – 1.55
2.25 – 2.30
2.25 – 2.30
2.17 – 2.22
2.33
2.33
1.55
1.60 – 1.65
**
**
**
Содержание ARE Series
Страница 27: ...ARE Series Chargers RS 759 Rev 11 4 8 FIGURE 4 3 MBC 3420B CABINET ASSEMBLY 24 CABINET 208 240 480 VOLT INPUT...
Страница 39: ...ARE Series Chargers RS 759 Rev 11 4 20 FIGURE 4 11 CONNECTION DIAGRAM FOR ARE 24 INCH CABINET 208 240 480 VAC...
Страница 40: ...ARE Series Chargers RS 759 Rev 11 4 21 FIGURE 4 12 CONNECTION DIAGRAM FOR ARE 30 INCH CABINET 120 208 240 VAC...
Страница 41: ...ARE Series Chargers RS 759 Rev 11 4 22 FIGURE 4 13 CONNECTION DIAGRAM FOR ARE 30 INCH CABINET 208 240 480 VAC...
Страница 42: ...ARE Series Chargers RS 759 Rev 11 4 23 FIGURE 4 14 CONNECTION DIAGRAM 36 INCH CABINET 120 208 240 VAC...
Страница 43: ...ARE Series Chargers RS 759 Rev 11 4 24 FIGURE 4 15 CONNECTION DIAGRAM FOR ARE 36 INCH CABINET 208 240 480 VAC...
Страница 45: ...ARE Series Chargers RS 759 Rev 11 4 26 FIGURE 4 17 SCHEMATIC DIAGRAM FOR ARE 24 INCH CABINET 208 240 480 VAC...
Страница 46: ...ARE Series Chargers RS 759 Rev 11 4 27 FIGURE 4 18 SCHEMATIC DIAGRAM FOR ARE 30 INCH CABINET 120 208 240VAC...
Страница 47: ...ARE Series Chargers RS 759 Rev 11 4 28 FIGURE 4 19 SCHEMATIC DIAGRAM FOR ARE 30 INCH CABINET 208 240 480VAC...
Страница 48: ...ARE Series Chargers RS 759 Rev 11 4 29 FIGURE 4 20 SCHEMATIC DIAGRAM FOR ARE 36 INCH CABINET 120 208 240 VAC...
Страница 49: ...ARE Series Chargers RS 759 Rev 11 4 30 FIGURE 4 21 SCHEMATIC DIAGRAM FOR ARE 36 INCH CABINET 208 240 480 VAC...
Страница 51: ...ARE Series Chargers RS 759 Rev 11 4 32 FIGURE 4 22 SCHEMATIC DIAGRAM FOR ARE CONTROL BOARD...
Страница 68: ...ARE Series Chargers RS 759 Rev 11 5 15 FIGURE 5 14 BLOCKING DIODE ASSEMBLY...