25. Note: Before reinstalling the the plastic cover, you must
first install a new fuse to reset the counter and avoid any error
messages. Use Uninet Reset Fuse #9362.
26. Use a small screwdriver to lift open the toner fill plug.
27. Toner plug lifted.
28. Using a thin needle or small hook tool, pry off the plastic
adhesive tab from the waste hopper openings (two holes)
shown. This is where the waste toner will dump out during
cleaning.
UNINET IMAGING INC.
•
BROTHER 1240/1650
•
ASSEMBLING THE TONER CARTRIDGE
UNINET IMAGING INC.
•
BROTHER 1240/1650
•
DISASSEMBLING THE TONER CARTRIDGE
UNINET IMAGING INC.
•
OKIDATA C5100 CARTRIDGE REMANUFACTURING INSTRUCTIONS