background image

10

 | Viper Cut 30 Manual

1. 

Connect the earth lead to the work piece.

2. 

Connect the air supply to the regulator located at the rear of the machine. Set Air Pressure to 0.5MPA (75psi)

3. 

Turn on the air supply. Set air supply to 5-6 Bar / 170 lpm.

1.

 Connect the earth lead to the work piece.

2.

  Connect  the  air  supply  to  the  regulator 

located at the rear of the machine. Set Air 
Pressure to 0.5MPA (75psi)

SET UP PROCEDURE FOR  

PLASMA CUTTING

Содержание Viper Cut 30

Страница 1: ...C30 OPERATING MANUAL Please read and understand this instruction manual carefully before the installation and operation of this equipment Welding Guns Of Australia PTY LTD 2018 1 YEAR WARRANTY Power S...

Страница 2: ...e us with market trends market feedback and customer comments and requirements Secondly they provide a customer support service that is second to none thus ensuring our customers have confidence that...

Страница 3: ...nty 2 Safety 4 AIR PLASMA CUTTING TECHNOLOGY 7 Viper Cut 30 Technical Data 8 Front Rear Layout 9 Set Up Procedure for PLASMA Cutting 10 Operating Procedure for PLASMA Cutting 12 SC30 Plasma Torch 16 T...

Страница 4: ...equently inspect input power cable for wear and tear replace the cable immediately if damaged bare wiring is dangerous and can kill Do not use damaged under sized or badly joined cables Do not drape c...

Страница 5: ...cylinder can explode Because gas cylinders are normally part of the welding cutting process be sure to treat them carefully CYLINDERS can explode if damaged Protect gas cylinders from excessive heat m...

Страница 6: ...to bring down the temperature inside the equipment The machine will be ready for use again when the internal temperature reaches safe level ii Over Voltage Supply Regarding the power supply voltage r...

Страница 7: ...riodic replacement The electrode has an insert of tough high conductive material such as hafnium and cerium This insert erodes with use also the tip orifice will erode with use Quality of the air used...

Страница 8: ...itable for a wide range of applications including sheet metal fabrication light industrial use site work automotive ducting work repair and maintenance services The VIPER CUT 30 gives you the best of...

Страница 9: ...4 Torch connection 5 Output connector connect to the work piece 6 Regulator 7 Primary power input cable 8 On Off switch 9 Air supply connector inlet connection Note the air regulator must be set to 5...

Страница 10: ...ted at the rear of the machine Set Air Pressure to 0 5MPA 75psi 3 Turn on the air supply Set air supply to 5 6 Bar 170 lpm 1 Connect the earth lead to the work piece 2 Connect the air supply to the re...

Страница 11: ...off switch located at the rear of the machine 5 Set the Amperage dial to the required setting 4 Connect the machine to the correct power supply and switch on the machine using the on off switch locate...

Страница 12: ...red depending on amperage A face shield is also recommended 2 Connect the Earth Clamp securely to the work piece or the work bench 3 Place and hold the torch vertical at the edge of the plate Note cut...

Страница 13: ...se and develops a pit in the end of the electrode when the pit becomes too much poor quality cuts will result and necessitate replacement of the electrode New Tip Worn Tip New Electrode Worn electrode...

Страница 14: ...ger to start the pilot arc The cutting arc will initiate when the torch tip is close enough to the work piece Start cutting on the edge until the arc has cut completely through Then proceed with the c...

Страница 15: ...tion When sparks are exiting from the bottom of the work piece the arc has pierced through the material When the pierce is complete proceed with cutting Safety Trigger Operation The Suregrip SC80 torc...

Страница 16: ...ead 11 SCSP1 Screw Pack to Suite Handle FRONT END CONSUMABLES Part No Description 4 WGSC2504 SC30 Electrode 5 WGSC2506 SC30 Swirl Ring 6 WGSC2520 09 SC30 Cutting Tip 7 WGSC2530 SC30 Retaining Cap 8 WG...

Страница 17: ...a clean dry area of the work piece 4 Faulty components in unit return for repair 5 Faulty Torch return for repair D Low cutting output 1 Incorrect setting of CURRENT A control check and adjust to prop...

Страница 18: ...e 3 UNI MIG Jasic Inverter MIG SWF Power Source Separate Wire Feeder Only 3 Years Clause 3 UNI TIG Jasic Inverter TIG Power Source Only 3 Years Clause 3 UNI MIG Water Cooler 1 Year Clause 3 T R Pulse...

Страница 19: ...the provisions outlined above and b Where the Goods are unable to be repaired the Goods are returned at your cost within thirty 30 days of the delivery date and c Welding Guns Of Australia PTY LTD wi...

Страница 20: ...uit Board Gun Plug House Cable Support Gas Connector Handle To Suit PP36 with Knobs All Xcel Arc Magmaweld MIG Welding Wires Electrodes Arc Leads Welding Cable Electrode Holder Earth Clamps TIG Weldin...

Страница 21: ...Viper Cut 30 Manual 21 NOTES...

Страница 22: ...22 Viper Cut 30 Manual NOTES...

Страница 23: ...Viper Cut 30 Manual 23 NOTES...

Страница 24: ...a Pty Ltd ABN 14 001 804 422 PO Box 3033 Lansvale NSW 2166 AUSTRALIA 112 Christina Rd Villawood NSW 2163 Phone 1300 864 644 Fax 02 9780 4244 Email sales unimig com au www unimig com au Welding Guns Of...

Отзывы: