31
RAZOR TIG 200 ACDC
OPERATING MANUAL
11. MMA: Machine Setup
1.
For DC+ electrodes, connect earth clamp to the
negative (-)
dinse connection, and electrode holder to
the
positive (+)
dinse connection.
2.
For DC- electrodes, connect earth clamp to the
positive (+)
dinse connection, and electrode holder to
the
negative (-)
dinse connection.
3.
Connect the plug into a power point, then switch the
machine ON.
4.
Ensure that MMA mode is activated on the front panel
by pressing the
WELD MODE
button.