![Unimig RAZOR COMPACT 250 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/unimig/razor-compact-250/razor-compact-250_operating-manual_3928773017.webp)
17
RAZOR COMPACT 250
OPERATING MANUAL
9. MIG Manual Mode
10. Synergic Mode
A
A
B
B
By default, the machine will be in Manual Mode when you are have selected
MIG
using the
WELD
MODE BUTTON.
In Manual MIG Mode the machine can be primarily adjusted using the
A
and
B
Adjustment Knobs.
Adjustment Knob A
will adjust your wire speed.
(Adjusted in meters per minute)
Adjustment Knob A
will adjust your amperage by default. Press the knob
to cycle through amperage, wire speed, and material thickness adjustment
modes based on your preference.
Adjustment Knob B
is for fine-tuning your synergic setup. You can adjust
voltage by default, as well as Inductance and Burnback by pressing the
knob in.
Note: Available adjustment voltage with Knob B is based on your settings with Knob A.
Adjustment Knob B
will adjust your voltage. Press the knob to cycle
through your
Inductance
and
Burnback Settings
.
Inductance:
(-10 through 10)
Burnback:
(0-800 milliseconds)
To activate Synergic mode, press the
Synergic Mode Button
while in MIG.
You will see the Synergic Mode indicator light to the right of the button light
up while Synergic Mode is active.
Using the
Material/Gas Selection Buttons
choose the metal you are welding and gas type you have
installed. Then choose the wire diameter using the
Wire Size Button.
SYN