D:S theoretical (=1/ IFOV theoretical) = 220:1
• D:S measure (=1/ IFOV
measure) is the spot size needed to provide an accurate
temperature measure.
• Typically
D:S measure is 2 to 3 times smaller than D:S theoretical, which means
the temperature measurement area of the target need to be 2 to 3 times larger
than that determined by the calculated theoretical D:S.
6.3.
Using the Multimeter with Thermal Imager
On IR+DMM mode, MODE key, RANGE key, HOLD key and REL Function is same
DMM mode.
6.3.1.
Memory and APP
Each Thermal imaging can be saved in the internal memory of the instrument
by pressing the navigator button in the direction indicated by the
“SAVE
”
.display. Download image into IR Ghost app for saved and create reports.
Install the IR GHOST app for iOS and Android systems.