Unika S-4000 Скачать руководство пользователя страница 12

page 11

UNiKA

 S-4000/S-5000/S-6000

Figure

Parallel Subwoofer Mode Speaker Set-Up

 19  

Figure

Stereo Subwoofer Mode Speaker Set-Up

 18  

S-4000 Rear Panel

CH-1 
Input

PARALLEL

STEREO

BRIDGE

NORMAL

SUB

CH-2 
Input

NORMAL

SUB

Either CH-1 
or CH-2 input, 
or Both inputs.

S-4000 Rear Panel

CH-1 
Input

PARALLEL

STEREO

BRIDGE

NORMAL

SUB

CH-2 
Input

NORMAL

SUB

Introduction      Front Panel      Rear Panel      Set Up      Speakon Assembly      

      Protection      Features      Specifications

Operating Modes

BRIDGE

MONO

_

+                   

+                   

+                   

_

CH-1

CH-2

_

PINOUT

1+

1-

POS NEG

CH- 2

PINOUT

2+

2-

POS NEG

CH- 2

1+

2+

POS NEG

BRIDGE

1+

1-

POS NEG

CH- 1

H-2

C

K

C

O

L

H-1

C

K

C

O

L

PARALLEL

STEREO

BRIDGE

THRU

PUSH TO RESET

FREQUENCY

20 Hz

20 Hz

200 Hz

200 Hz

FREQUENCY

CH-2

CH-1

~120VAC  60Hz

THRU

INPUT

GAIN

INPUT

NORMAL
SUB

0.775V

1V

1.44V

NORMAL
SUB

INPUT

BRIDGE

MONO

_

+                   

+                   

+                   

_

CH-1

CH-2

_

PINOUT

1+

1-

POS NEG

CH- 2

PINOUT

2+

2-

POS NEG

CH- 2

1+

2+

POS NEG

BRIDGE

1+

1-

POS NEG

CH- 1

H-2

C

K

C

O

L

H-1

C

K

C

O

L

PARALLEL

STEREO

BRIDGE

THRU

PUSH TO RESET

FREQUENCY

20 Hz

20 Hz

200 Hz

200 Hz

FREQUENCY

CH-2

CH-1

~120VAC  60Hz

THRU

INPUT

GAIN

INPUT

NORMAL
SUB

0.775V

1V

1.44V

NORMAL
SUB

INPUT

Use either the bare wire 
or the banana jacks

Use either the bare wire 
or the banana jacks

Use either the bare wire 
or the banana jacks

Use either the bare wire 
or the banana jacks

Содержание S-4000

Страница 1: ...res 14 Specifications UNiKA POWER ON OFF LIMITER ON PROFESSIONAL POWER AMPLIFIER LIMITER ON PARALLEL STEREO BRIDGE 20dB SIGNAL 10dB 5dB CLIP PROTECT 0 10 0 10 CH A CH B POWER ON OFF LIMITER ON PROFESSIONAL POWER AMPLIFIER LIMITER ON PARALLEL STEREO BRIDGE 20dB SIGNAL 10dB 5dB CLIP PROTECT 0 10 0 10 CH A CH B POWER ON OFF LIMITER ON PROFESSIONAL POWER AMPLIFIER LIMITER ON PARALLEL STEREO BRIDGE 20d...

Страница 2: ... lisez les avertissements supplémentaries situés dans le guide Ce symbole est utilisé pour indiquer à l utilisateur qu il trouvera d importantes instructions importantes sur l utilisation et l entretien de l appareil dans la littérature accompagnant le produit Dieses Symobl soll den Anwender vor unisollierten gefährlichen Spannungen innerhalb des Gehäuses warnen die von Ausreichender Stärke sind u...

Страница 3: ...The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the unit C The appliance has been exposed to rain or water D The fixture does not appear to operate normally or exhibits a marked change in performance Congratulations and thank you for purchasing S 4000 S 5000 S 6000 amplifier These amplifiers are representation of UNiKA s continuing commitmen...

Страница 4: ...d Filter S Series amplifiers are cooled by two rear mounted fans Cool air from front grills is filtered and flows over the heatsinks and exhausts to back side Make sure these outlets remain clear to allow unrestricted air flow 3 AC Power Switch S Series amplifiers have a front panel AC mains power switch 4 Channel 1 Gain Control This rotary knob is used to control the output signal of channel one ...

Страница 5: ... These connectors accept input signals on balanced TRS and XLR input plugs Connectors for each channel are in parallel the unused connectors may be used for loop through connection to other amplifiers XLR pin setting Pin 3 signal Negative Pin 2 signal Positive Pin 1 Ground TRS pin setting Tip signal Positive Ring signal Negative Sleeve Ground 26 Reset Button This button is designed to protect the ...

Страница 6: ...r other device For example Connect a XLR cable to the input of channel one You may now connect a XLR cable from the channel one Input Thru jack to the input jack of another amplifier s channel one input This will reduce the use of Y cables OUTPUTS BINDING POST BANANA PLUG Connect your speakers to the binding post outputs on the rear of the amplifier The speaker wire may be connected by bare wire d...

Страница 7: ...BRIDGE CONNECTIONS Mono bridge operation connections will follow the above descriptions however when operating in mono bridge operation the speaker connections will run between the two positive red leads Use channel two positive output terminal for the negative connection and the channel one positive output terminal for the positive connection Typical speaker output using bare wire Insert bare wir...

Страница 8: ...ector insert B into the connector housing A making sure that the large notch on the outer edge of the insert lines up with the large groove on the inside of the connector housing The insert should slide easily through the housing and out the other side until it extends approximately 3 4 inch from the end of the housing 6 Slide the cable tensioner D along the cable and insert into the housing A mak...

Страница 9: ...ies the two channel line inputs together so that they will both be driven by the same signal without the need for external jumpers or wiring Both amplifier channels will operate independently Though they carry the same signal their gain controls affect only their respective channels and they both must use their respected speaker outputs Never attempt to parallel the speaker outputs this may cause ...

Страница 10: ...g Modes BRIDGE MONO _ _ CH 1 CH 2 _ PINOUT 1 1 POS NEG CH 2 PINOUT 2 2 POS NEG CH 2 1 2 POS NEG BRIDGE 1 1 POS NEG CH 1 H 2 C K C O L H 1 C K C O L PARALLEL STEREO BRIDGE THRU PUSH TO RESET FREQUENCY 20 Hz 20 Hz 200 Hz 200 Hz FREQUENCY CH 2 CH 1 120VAC 60Hz THRU INPUT GAIN INPUT NORMAL SUB 0 775V 1V 1 44V NORMAL SUB INPUT BRIDGE MONO _ _ CH 1 CH 2 _ PINOUT 1 1 POS NEG CH 2 PINOUT 2 2 POS NEG CH 2 ...

Страница 11: ...s frequency output level Frequencies may be adjusted from 20Hz to 200Hz Page 11 Figure 18 details a typical Stereo Subwoofer set up PARALLEL SUBWOOFER This operation is similar to the Stereo Subwoofer operation but in parallel When running subwoofers it is usually recommended to run them in mono mode to achieve a cleaner tighter low end This operation allows you to run several subwoofers down to a...

Страница 12: ...2 POS NEG BRIDGE 1 1 POS NEG CH 1 H 2 C K C O L H 1 C K C O L PARALLEL STEREO BRIDGE THRU PUSH TO RESET FREQUENCY 20 Hz 20 Hz 200 Hz 200 Hz FREQUENCY CH 2 CH 1 120VAC 60Hz THRU INPUT GAIN INPUT NORMAL SUB 0 775V 1V 1 44V NORMAL SUB INPUT BRIDGE MONO _ _ CH 1 CH 2 _ PINOUT 1 1 POS NEG CH 2 PINOUT 2 2 POS NEG CH 2 1 2 POS NEG BRIDGE 1 1 POS NEG CH 1 H 2 C K C O L H 1 C K C O L PARALLEL STEREO BRIDGE...

Страница 13: ...el Clipping should be kept to a reasonable minimum An amplifier s peak current draw at full output power into 2 ohms is several times what the normal draw is but its various protection circuits will prevent this condition lasting more than a minute or two SHORT CIRCUIT PROTECTION The S Series amplifier comes with built in Output Short Circuit Protects The Output Short Circuit Protection protects t...

Страница 14: ...mplifiers are designed with SMPS power with CLASS H S 5000 S 6000 and CLASS AB S 4000 of Power Stage Topology instead of the traditional toroidal transformer therefore the total weight of the amplifier is ultra light and also the complete performance is better THRU THRU will allow the user to daisy chain one amplifier s signal input into another amplifier Plug the signal source outputs into the fi...

Страница 15: ...r 8 ohms 1dB Total Harmonic Distortion 20Hz 20KHz rated output power 8 ohms 0 02 Crosstalk 1KHz 70dB Damping Factor 400 Signal To Noise Ratio below rated output power 20Hz to 20KHz A Weighted 80 dB Power Consumption rated output power 8 ohms 12 54A 110V 17 45A 110V 24 36A 110V Output Circuitry CLASS AB CLASS H CLASS H Cooling System Dual 2 Speed Fan and Heatsinks Dimensions Height x Width x Depth ...

Страница 16: ...Professional Power Amplifiers UNiKA ...

Отзывы: