Unika MP-2800 Скачать руководство пользователя страница 13

PROTECTION

LIMITER -

 

The MP-2800/MP-4000/MP-5000 amplifiers comes with a built in limiter. When the input signal overloads, the “CLIP LED” indicates a signal overload, at this 

time, the volume should be lowered to reduce distortion. If the input gain level is not reduced the built-in limiter will activate. During signal overload, the limiter will reduce 
the input audio signal enough to minimize the amount of clipping. A limiter takes the gain of an overloading signal and reduces it, the reduction in gain reduces distortion 
that can cause damage to your speakers and amplifier. During normal operation below clipping, and momentary clips on peaks, the limiter does not affect the audio 
signal and is inaudible. It will allow brief clipping of peaks and will only activate when continuous hard clipping occurs. During excessive clipping the limiter will reduce 
the audio signal enough to minimize the amount of clipping. When the input signal decreases enough that clipping ends, the limiter will deactivate and cease its gain 
reduction. The limiter has a fixed threshold and can not be adjusted. 

SAFE POWER LEVELS AT DIFFERENT OUTPUT LOADS:

8-Ohm Loads : 

The amplifier can operate at its rated power level without risk of overheating. However, it may caused excessive temperature if it is pushed hard enough 

to continually light the “CLIP” indicator, the amplifier’s average output power can reach its maximum peak.

4-Ohm Loads : 

If the “CLIP” indicator flashes occasionally, the amplifier is approaching its Maximum long-term power capacity. If it is lit about half the time, the amplifier 

channel will probably go into thermal protection within a few minutes.

2-Ohm Loads : 

Except for an occasional flash, keep the “CLIP” indicator dark to avoid overheating the amplifier channel. Clipping should be kept to a reasonable 

minimum. An amplifier’s peak current draw at full output power into 2 ohms is several times what the “normal ” draw is, but its various protection circuits will prevent this 
condition lasting more than a minute or two.

page 12

SHORT CIRCUIT PROTECTION -

 

The MP-2800/MP-4000/MP-5000 amplifiers comes with built-in Output Short Circuit Protects. 

The Output Short Circuit Protection protects the output devices of the amplifier from short circuits and stressful loads. If your speaker 
lines shorted, the amplifier automatically detects this problem and discontinued operation for that channel. If one side of your amplifier 
becomes shorted and goes into protect mode, the other side will continue to operate normally. Channel output during the “Short Circuit 
Protection" will be interrupted (i.e. no sound output). Short Circuit Protection can usually be traced back to the signal output line (i.e. 
speaker line). Check the line from the output terminal of the amplifier to the speaker. If this line is good, check the internal speaker 
connections and components. A short circuit will usually be traced to a bad cable or a bad speaker component and is rarely traced to 
the amplifier itself.

Introduction      Front Panel      Rear Panel      Set Up      Speakon Assembly      Operating Modes      

      Features      Specifications

Protection

UNiKA

 MP-2800/MP-4000/MP-5000

THERMAL PROTECTION - 

Dual variable speed fans on the MP-2800/MP-4000/MP-5000 amplifiers provide adequate cooling. During low level output the 

fans run at normal speeds. During high output and as heat raises, (exceeding 90°C.), the fans will run at higher speeds to aid the cooling process. If the heatsink 

temperature exceeds 91°C., the amplifier will mute until the amplifier cools down. When the amplifier cools below 90°C., the amplifier will return to normal 

operations. Be sure not to operate your amplifier below the minimum load ratings to reduce the risk of overheating problems.

Содержание MP-2800

Страница 1: ...rating Modes 12 Protection 13 Features 14 Specifications UNiKA STEREO BRIDGE PARALLEL SIGNAL SIGNAL CLIP CLIP 0 10 0 10 LIMITER LIMITER POWER OFF ON CHANNEL 1 CHANNEL 2 ON ON MP 2800 PROFESSIONAL AMPL...

Страница 2: ...es avertissements suppl mentaries situ s dans le guide Ce symbole est utilis pour indiquer l utilisateur qu il trouvera d importantes instructions importantes sur l utilisation et l entretien de l app...

Страница 3: ...has been damaged B Objects have fallen or liquid has been spilled into the unit C The appliance has been exposed to rain or water D The fixture does not appear to operate normally or exhibits a marke...

Страница 4: ...Mode 4 UNiKA Logo and Model No MP series have 3 types of 3U Models MP 2800 MP 4000 MP 5000 5 Fan Inlet Grills and Filter MP Series amplifiers are cooled by two rear mounted fans Cool air from front gr...

Страница 5: ...d to send a parallel signal from the channel 2 input jack to another device or amplifier 18 Mode Selection Switch This recessed three position switch configures the amplifier for Stereo Parallel or Br...

Страница 6: ...onnect a XLR cable to the input of channel one You may now connect a XLR cable from the channel one Input Thru jack to the input jack of another amplifier s channel one input This will reduce the use...

Страница 7: ...ll run between the two positive red leads Use channel two positive output terminal for the speaker s negative connection and the channel one positive output terminal for the speaker s positive connect...

Страница 8: ...rly match the positive and negative leads of each wire Figure 13 5 Slide the connector insert B into the connector housing A making sure that the large notch on the outer edge of the insert lines up w...

Страница 9: ...external jumpers or wiring Both amplifier channels will operate independently Though they carry the same signal their gain controls affect only their respective channels and they both must use their r...

Страница 10: ...15 TYPICAL MONO BRIDGE SET UP PARALLEL STEREO BRIDGE Either CH 1 or CH 2 input or Both inputs PARALLEL STEREO BRIDGE NORMAL FREQUENCY NORMAL SUB WOOF FREQUENCY CH 1 20 Hz 20 Hz 200 Hz 200 Hz CH 2 INPU...

Страница 11: ...the amplifier to control the frequency output level Frequencies may be adjusted from 20Hz to 200Hz Page 10 17 details a typical Bridge Subwoofer set up Figure STEREO SUBWOOFER This operation is simila...

Страница 12: ...ither the bare wire or the banana jacks Use either the bare wire or the banana jacks Figure Stereo Subwoofer Mode Speaker Set Up 18 Use either the bare wire or the banana jacks Use either the bare wir...