M12927CA
C
8 oPE
Safety output value
-100... 100
0
C
9 io4.F I/O4 function selection
on = Out4 will be ever ON (used as a transmitter
power supply) ,out4 = Uscita 4 (Used as digital
output 4), dG2c = Digital input 2 for contact
closure, dG2U = Digital input 2 driven by 12... 24
VDC
on
C
10 diF1
Digital input 1 function
oFF = Not used,
1 = Alarm reset,
2 = Alarm acknowledge (ACK),
3 = Hold of the measured value,
4 = Stand by mode,
5 = Manual mode,
6 = HEAt with SP1 and CooL with SP2,
7 = Timer RUN/Hold/Reset,
8 = Timer Run,
9 = Timer Reset,
10 = Timer Run/Hold,
11 = Timer Run/Reset,
12 = Timer Run/Reset with lock,
13 = Program Start,
14 = Program Reset,
15 = Program Hold,
16 = Program Run/Hold,
17 = Program Run/Reset,
18 = Sequential SP selection,
19 = SP1 - SP2 selection,
20 = SP1... SP4 binary selection,
21 = Digital inputs in parallel
19
C
12 di.A
Digital Inputs Action
(DI2 only if configured)
0 = DI1 direct action, DI2 direct action
1 = DI1 reverse action, DI2 direct action
2 = DI1 direct action, DI2 reverse action
3 = DI1 reverse action, DI2 reverse action
0
Out GROUP- Output parameters
Liv N° Param
Description
Values
Default
C
14 o1F
Out 1 function
AL = Alarm output
AL
C
15 o1AL
Initial scale value of the analog retransmission -1999 ... Ao1H
1
C
18 o1Ac
Out 1 action
dir = Direct action
rEU = Reverse action
dir.r = Direct with reversed LED
ReU.r = Reverse with reversed LED
rEUr.r
C
19 o2F
Out 2 function
H.rEG = Heating output
H.rEG
C
21 o2Ac
Out 2 action
dir = Direct action
rEU = Reverse action
dir.r = Direct with reversed LED
ReU.r = Reverse with reversed LED
dir
C
22 o3F
Out 3 function
H.rEG = Heating output
H.rEG
C
24 o3Ac
Out 3 action
dir = Direct action
rEU = Reverse action
dir.r = Direct with reversed LED
ReU.r = Reverse with reversed LED
dir
AL1 GROUP - Alarm 1 parameters
Liv N° Param Descrizione
Values
Default
C
28 AL1t
Tipo allarme AL1
nonE = Alarm not used
LoAb = Absolute low alarm
HiAb = Absolute high alarm
LHAo = Windows alarm in alarm outside the
windows
LHAI = Windows alarm in alarm inside the
HidE
9
Содержание RN510
Страница 39: ......
Страница 54: ......
Страница 63: ......
Страница 64: ......
Страница 65: ...RWF50 2x RWF50 3x User manual M12922CB Rel 1 0 07 2012...
Страница 80: ...16 Note Specifications and data subject to change Errors and omissions excepted...
Страница 81: ...KM3 Modulator USER MANUAL M12927CA Rel 1 0 10 2020...
Страница 82: ...M12927CA MOUNTING 2...
Страница 98: ...1 RWF55 5X RWF55 6X User manual M12926CA Rel 0 1 10 2015...
Страница 99: ...2 DEVICE INSTALLATION Fixing system Drilling dimensions...
Страница 120: ......
Страница 121: ...23 Note Specifications and data subject to change Errors and omissions excepted...
Страница 130: ...OFF...
Страница 131: ......
Страница 132: ......
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ......
Страница 137: ......
Страница 138: ......