Fully-modulating burners connectors:
Key
C1
LOW FLAME TIME METER
C2
HIGH FLAME TIME METER
FU1
FAN MOTOR LINE FUSE
FU3
LINE FUSE
IL
BURNER LINE SWITCH
IM
FAN MOTOR LINE SWITCH
KM1
FAN MOTOR CONTACTOR
LAF
BURNER IN HIGH FLAME INDICATOR LIGHT
LB
INDICATOR LIGHT FOR BURNER LOCK-OUT
LBF
BURNER IN LOW FLAME SIGNALLING LAMP
MV
FAN MOTOR
ST
THERMOSTATS O PRESSURE SWITCHES SERIE
TAB
HIGH LOW FLAME THERMOSTAT/PRESSURE SWITCH
TS
SAFETY THERMOSTAT/PRESSURE SWITCH
CONN-MOTORE FAN MOTOR CONNECTOR
CONN-LINEA BURNER POWER SUPPLY CONNNECTOR
CONN-TAB HIGH-LOW FLAME CONNECTOR
($)
IF "TAB" USED REMOVE THE BRIDGE BETWEEN TERMINALS
T6-T8
Fig. 9 - Probes connection by 7-pins connecto
r
Key
C1
LOW FLAME TIME METER
FU1
LINE FUSE FOR FAN MOTOR
FU3
LINE FUSE
FU4
AUXILIARY FUSE
IL
BURNER LINE SWITCH
IM
FAN MOTOR LINE SWITCH
KM1
FAN MOTOR REMOTE CONTACTOR
SIEMENS RWF40
MODULATION REGULATOR
LB
BURNER LOCKOUT SIGNALLING LAMP
LBF
BURNER IN LOW FLAME SIGNALLING LAMP
MV
FAN MOTOR
SD-0÷10V
VOLTAGE SIGNAL
SD-0/4÷20mA
CURENT SIGNAL
SD-PRESS
PRESSURE PROBE
SMA
MAN/AUTO SELECTOR
SMF
OPERATION SELECTOR MIN-0-MAX
ST
PRESSURE SWITCHES OR THERMOSTATS SERIE
TS
SAFETY THERMOSTAT/PRESSURE SWITCH