23
MAINTENANCE MANUAL
LEGEND cod. 05-483 rev.3
BP
-
Pump motor remote contactor coil
BV
-
Fan motor remote contactor coil
CAP
-
Pump motor auxiliary contacts contactor
CM
-
Manual operation switch 0) off 1) gas 2) light oil
CP
-
Pump motor contactor
CR1/2
-
Relay contacts
CTP
-
Pump motor overload contacts
CTV
-
Fan motor contacts
CV
-
Fan motor contactor
EV1
-
Gas electro-valve upstream DUNGS DMV..
EV2
-
Gas electro-valve downstream DUNGS DMV..
EVG1-EVG2
-
Light oil electro-valve inlet
EVG3-EVG4
-
Light oil electro-valve return
F
-
Fuses
FC
-
UV flame detector
IG
-
Main switch
L
-
Phase
LAF
-
Burner in high flame indicator light
LB
-
Burner lockout indicator light
LBF
-
Burner in low flame indicator light
LEV1
-
Indicator light for opening of electro-valve EV1
LEV2
-
Indicator light for opening of electro-valve EV2
LEVG
-
Indicator light for opening of electro-valves light oil
LFL1.322
-
LANDIS flame monitor device
LPGMIN
-
Indicator light for presence of gas in the network
LS
-
Indicator light for burner in stand-by (STAND-BY)
LSPG
-
Indicator light for leakage of valves
LT
-
Indicator light for fan overload tripped
LTA
-
Ignition transformer indicator light
MA
-
Supply terminal block
MC
-
Terminal block for connection of burner components
MP
-
Pump motor
MV
-
Fan motor
N
-
Neutral
PA
-
Combustion air pressure switch
PGMAX
-
High gas pressure switch (where supplied, remove the bridge between
terminal 156 and 158 in terminal block MC)
PGMIN
-
Low gas pressure switch
POMAX
-
High light oil pressure switch
POMIN
-
Low light oil pressure switch
PS
-
Lockout reset button
R1/2
-
Auxiliary relay
SQL33
-
LANDIS servo control for air damper
ST
-
Series thermostats or pressure switches
TA
-
Ignition transformer
TAB
-
High/low thermostat (where supplied, remove the bridge between
terminals 6 and 7 in terminal block MA)
TP
-
Pump motor thermal
TV
-
Fan motor thermal
VPS504
-
Dungs valve leakage monitor device (where supplied, remove the bridge
between terminal 177 and 178 in terminal block MC)
SERVO CONTROL CAMS
Y1
-
High flame
Y2
-
Start-up and Ignition gas or light oil flame
Y3
-
Low flame
WARNING :
1 - Electrical supply 400V 50Hz 3N a.c.
2 - Do not reverset phase with neutral
3 - Ensure burner is properly earthed
ELECTRICAL DIAGRAM (code 05-483 Rev.03)
Содержание HP60
Страница 4: ......
Страница 5: ......
Страница 24: ...24 MAINTENANCEMANUAL ELECTRICAL DIAGRAM code 05 483 Rev 03...
Страница 25: ...25 MAINTENANCEMANUAL...
Страница 32: ...32 MONARCH OIL NOZZLE Mod F80 BPS APPENDIX...
Страница 33: ...33 BERGNZO OIL ZOZZLE Mod A3 APPENDIX...
Страница 34: ...34 FLUIDICS OIL NOZZLE Mod K3 APPENDIX...
Страница 35: ...35 FLUIDICS OIL NOZZLE Mod KC2 APPENDIX...