PART II: INSTALLATION
22
1. Inlet G1/2
2. To the nozzle G1/2
3. Return G1/2
4. Pressure gauge port G1/4
5. Vacuum gauge port G1/4
6. Pressure governor
Connecting the oil flexible hoses to the pump
To connect the flexible oil hoses to the pump, proceed as follows, according to the pump provided:
1
remove the closing nuts A and R on the inlet and return connections of the pump;
2
screw the rotating nut of the two flexible hoses on the pump
being careful to avoid exchanging the lines
: see the arrows marked
on the pump.
For further information, refer to the technical documentation of the pump.
.
Diesel filters
Suntec TA..
Oil viscosity
3 ÷ 75 cSt
Oil temperature
0 ÷ 150°C
Min. suction pressure
- 0.45 bar to avoid gasing
Max. suction pressure
5 bar
Max. return pressure
5 bar
Rotation speed
3600 rpm max.
Suntec T+TV
HP Technik UHE-A
Suntec TA
R
A
R
A
R
A
Item
Note
Connection
Max. operating
pressure
Max. operating
temperature
Filtering
degree
Protec-
tion
5
20151PE (*)
-
3/8”
1 bar
-20, 60 °C
100
μ
-
6
20201PL (*)
-
3/8”
1 bar
-20, 60 °C
100
μ
-
7
GA70501
-
1”
4 bar
90 °C
100
μ
IP65
(*) Supplied per pilot diesel fuel if present