Basic Communication Procedures
Nur für den internen Gebrauch
A31003-S2000-R102-16-7620 02/2016
82
Provisioning Service, Developer’s Guide
c03.fm
Error Handling
3.8.3
Example 3: Item is Read Only
1. The phone initiates a connection to the provisioning service.
<WorkpointMessage xsi:schemaLocation="http://www.siemens.com/DLS"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xmlns="http://www.siemens.com/DLS">
<Message nonce="71E7F7FF699CE4467956071307E7478F"
maxItems="-1">
<ReasonForContact>solicited</ReasonForContact>
<ItemList>
<Item name="device-type">OpenStage 80</Item>
<Item name="related-device-type">OpenStage 80</Item>
<Item status="failed" name="gigabit-ethernet"></Item>
<Item name="software-type">Siemens SIP</Item>
<Item name="related-software-type">Siemens SIP</Item>
<Item name="software-version">V1 R5.6.53</Item>
<Item name="related-software-version">V1 R5.6.53</Item>
<Item name="contact-me-uri">
http://192.168.233.195:8085/contact_dls.html/ContactDLS</Item>
<Item name="mac-addr">00:01:E3:25:E1:CB</Item>
<Item name="configuration-changed-flag">false</Item>
<Item name="part-number">Unknown</Item>
<Item name="sip-mobility-state">1</Item>
<Item name="e164">5419431261</Item>
<Item name="user-pwd">111111</Item>
<Item status="failed" name="user-pwd-unicode"></Item>
<Item name="basic-e164">5419431261</Item>
<Item name="mobility-enabled">true</Item>
</ItemList>
</Message>
</WorkpointMessage>
2. The provisioning service attempts to write a data item that is read-only at the phone.
<DLSMessage xmlns="http://www.siemens.com/DLS"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:schemaLocation="http://www.siemens.com/DLS">
<Message nonce="71E7F7FF699CE4467956071307E7478F">
<Action>WriteItems</Action>
<ItemList>
<Item name="device-type">OpenStage 75</Item>
</ItemList>
</Message>
</DLSMessage>