Configuration and activation
A31003-M2000-M103-2-76A9, 07/2014
3-13
Alarm and Emergency Call Configuration, Administrator Documentation
SHB_PNG-Konfig.fm
Configuration menu
6.
Change the values of the following parameters:
Table 3-10
Parameter – [Mode] Activation
Parameters
Operating Mode
Value Range
Standard Value
Automatic
BM/AM/PNG
On/off
Off
Manual
BM/AM/PNG
On/off
On
7.
Confirm with
Save
.
3.2.1.3
Control Ports
>
Basic Mode and Alarm Mode: Alarm Mode can be activated after deleting the
Start
,
NOK
and
Stop
Availability ports without logging on to the alarm server.
The sensor check required in Alarm Mode is then also not performed.
The control ports are phone numbers of the alarm server that are used for signalling the states/
events between the handset and the alarm server.
The phone numbers of the control ports are entered automatically in Alarm Mode and PNG
Mode if the
Control Port Basic
parameter has been configured in Alarm Mode or PNG Mode.
The control ports can then also be modified individually. The three control ports in Basic Mode
have to be entered individually.
For more information on control ports please refer to Chapter 4, "Control ports and alarm
destinations".
Procedure:
1.
Select the
Additional Features
icon in the main menu.
2.
Select
Configuration
.
3.
Enter the five-position service PIN and confirm with
OK
.
4.
Select one of the three operating modes.
5.
Select
Control Ports
.
6.
Change the values of the following parameters: