SHB_PNG-Konfig.fm
A31003-M2000-M103-2-76A9, 07/2014
Alarm and Emergency Call Configuration, Administrator Documentation
3-10
Configuration and activation
Configuration menu
8.
Confirm with
Save
.
Escape Alarm
The Escape Alarm can be activated optionally. It is triggered if the sensors identify undue
violent movement of the handset over a defined configurable period of time.
For more information on alarm destinations please refer to Chapter 4, "Control ports and alarm
destinations".
Procedure:
1.
Select the
Additional Features
icon in the main menu.
2.
Select
Configuration
.
3.
Enter the five-position service PIN and confirm with
OK
.
4.
Select one of the three operating modes.
5.
Select
Alarms
.
6.
Select
Escape Alarm
.
7.
Change the values of the following parameters:
Table 3-7
Parameter – Escape Alarm
Parameters
Operating Mode
Value Range
Standard Value
Activation
BM/AM/PNG
On/off
Off
Response Time
BM/AM
10 ... 900 s
30 s
PNG
10 ... 90 s
30 s
Prealarm Time
BM/AM
0 ... 300 s
15 s
PNG
0 ... 30 s
15 s
Empfindlichkeit
BM/AM/PNG
Low / Medium / High Medium
Alarm Destination
BM
-
1
1
The alarm destination is the same in Basic Mode of the M3 Plus for all alarms and is entered under "General Settings".
112
AM/PNG
(up to 32 digits)
(blank)
Alarm Destination
BM
-
1
112
AM/PNG
(up to 32 digits)
(blank)
1
The alarm destination is the same in Basic Mode of the M3 Plus for all alarms and is entered under "General Settings".
Parameters
Operating Mode
Value Range
Standard Value
Table 3-6
Parameter – Time Alarm