c07.fm
Diagnosis and Maintenance
Testing the Radio Area
A31003-C1020-S100-03-7620, 12/2017
OpenScape Cordless IP V2, Service Documentation
87
RSSI
(radio signal)
Field strength of the radio signals received from the base
station, normalized to a maximum of 100. If the value is
< 50, the radio connection to the base station is no longer
guaranteed.
Acceptable field strength is > 50 (> -60 dBm).
Frequency
Frequency (0 – 9)
Time slot
(Slot)
Time slot (0 – 11) of the receiving channel on which the
measurement is carried out.
RPN
(port number)
IDECT IP base station identification based on the RPN (Radio
Fixed Part Number), e.g. 018. If the handset switches on at/over
to an overlapping radio cell/DECT IP base station, the current
DECT IP base station appears on the handset display. The RPN
is indicated in hex format in Gigaset S3 professional and
Gigaset SL3 professional handsets.
Example: RPN 018 will be display in the Gigasets as HEX-value
012H. The identifier "H" shows clearly the hexadecimal
presentation.
FRAQ
(frame quality)
Transmission quality in %.
95% to 100% satisfactory (for short periods 90% to 94% non-
critical), < 95% faulty.
095-3-02-012H-100
SAVE
OFF
Measurement result
RSSI
Frequency
Time slot
RPN
FRAQ
Handset display,
forexample