S e c t i o n 4 - I n s t a l l a t i o n
63
Unpacking the Main Equipment
Static handling precautions must be observed when handling this system.
Remove the telephone system from shipping carton and lay it flat on a stable working surface
with the cover facing upwards. Remove the 2 screws on the front of the case and remove the
plastic side-cover to access the MDF connection terminals.
Inspect the main unit housing for damage during product delivery.
The resources listed below are all necessary for a working system.
Main system
Single Line Telephones or System terminals
UTP twisted pair cables
PSTN Exchange Lines or ISDN basic rate line.
Mounting the System
When mounting the telephone system care should be taken to ensure all cables and AC cords are
neatly arranged. The telephone system should not be mounted directly onto masonry, concrete, or
other surface subject to moisture or condensation. (Use a plywood backing board when mounting to
these types of surfaces). A drill template is provided for mounting the system onto the wall. The
screw fasteners chosen should be the correct type for the wall surface and capable of supporting the
full cabinet weight.
Two #10 screws approximately 40mm long are required to locate into the slots provided on the rear
of the Main Equipment as shown in Figure 4-1 below.
Figure 4-1 Rear View of Telephone System
Preliminary Procedures
After the case has been wall mounted, connect one exchange line, and two extension telephones (11
and 12)
Exchange Line 1 must be connected to EXCHANGE terminals marked CO1, line 2 to CO2,
line 3 to CO3, line 4 to CO4, line 5 to CO5 and line 6 to CO6.
A DTMF telephone (or Executive Terminal) must be fitted to EXTENSION terminals
marked ext 12 (206 only) ext.13 (208/212 only). This is the Master Extension and is used for
system programming.
Lift the handset at Extension 11 (a power fail telephone) and listen for PSTN dial tone, before
power up. Verify that you can directly dial external numbers, without the normal prefix 0 for a
line.
Power up Sequence
Turn on the 220 – 240VAC supply, then wait about 10 seconds.
Wait until the green LED on the front cover is on and flashing.
Call between Extension 12 and extension 11, by dialling the extension number 11 or 12.
Important!
Screw housing
slots for wall
mounting
Serial number