The system is programmed and ready to go. You may set up more advanced features by following
the instructions in the system programming section, starting on page 19.
Telephone System Installation
The installer must visually check the Telephone System main equipment before actual power-up and
making wiring connections to ensure correct programming and subsequent operation of the system.
This check must include:
An inspection of the main unit housing for damage during product delivery.
An inspection of the fitted 220-240VAC Power Cord & Plug.
An inspection of integral MDF wiring terminals for appropriate screw terminals (Side Cover
Removal).
Installation Checklist
Before starting installation, remember the following points:
Always disconnect the mains during installation.
Inspect the fitted Power Cord & Plug.
Twisted Pair cable must be used to support all extensions and system integral devices.
Independent cables to be used for each terminal. Four-wire (2 pair) cable must be used for
Terminal wiring on the 206/208 systems. Single pair wiring is required on the 212 system.
Install an Executive Terminal at the master extension 12 on 206, 13 on 208/212 for system
programming. A DTMF single line telephone may also be used but it will lack menu driven
operation.
The system has a REN of 1 per exchange line and 3 per extension. Do not exceed the limit.
Locating the Telephone System
The location selected for the telephone system should be clean, dry, temperature controlled and
accessible to authorised personnel only. When selecting a site it is important to consider the
following:
Availability of a 220-240V AC mains power socket located within 2m of the system. Additional
outlets for a paging amplifier and music source if needed.
The unit is designed for wall mounting.
Proximity to the C.O. line / system line terminations.
Proximity of the extension telephone locations so that the prescribed cable lengths are not
exceeded.
A well-ventilated area having a temperature range of 0-50
°
C with a recommended temperature
range of 20-26
°
C and a humidity range of 10-95% (non-condensing).
Lighting and accessibility of the system for maintenance.
The Telephone System must not be subjected to harsh environmental conditions. To ensure easy
servicing and reliable operation, several factors must be considered when planning the system
installation. The following locations are to be avoided at installation sites:
Avoid heat-producing or steam producing equipment.
Avoid Areas with temperature and humidity extremes.
Avoid installation near a passageway or aisle used for moving machinery or vehicles.
Avoid installation near equipment that generates high electromagnetic interference. Possible
sources are photocopiers, computer terminals, mobile phones fluorescent tube light fittings and
electrical machinery.
Avoid areas liable to flooding, near flammable materials, excessive dust, vibration or mechanical
stress.