Transport, dimensions, installation, intermediate storage
UNIFLEX-Hydraulik -
26 – www.uniflex.de
Figure 4-4 Power unit installation
Mount the power unit in the immediate
vicinity of the device on a solid work-
bench and fix it using
four machine screws M 8
using the hole pattern
140 x 140 mm.
The machine screws M 8 are
not included with the device.
4.3.1 Required utilities
Make sure that the following utilities are provided upon delivery of the
device:
Voltage /
Frequenz
Mot.
Nennstrom A
Volllast
350 bar
Ohne Last
Einstellung
Type UA4_ MVC
(220V – 240V)
230V 50Hz 7,8
9,6
3,9
10,0
230V 60Hz 5,4
11,2
3,7
12,0
Type UA4_08_11
(220V – 240V)
115V 50Hz 15,5
20,8
7,4
15,5
115V 60Hz 10,7
24,3
7,1
16,0
Capacity 1
kW
Back-up fuse
1 x 16 A
Table 4-2 Electric power supply