![Uniflame GLT1343SP Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/uniflame/glt1343sp/glt1343sp_owners-manual_3802174008.webp)
LP Gas Outdoor Fire Bowl Model No. GLT1343SP
Troubleshooting
Problem
Possible Cause
Prevention/Cure
Burner will not light with match
No gas flow
Check if LP gas tank is empty
A. If empty, replace
B. If LP gas tank is not empty, refer to “Sudden drop in gas flow or reduced
flame height”
LP gas tank is low or empty
Replace LP gas tank
LP gas leak
Follow “Checking for Leaks” instructions in the owner’s manual
Coupling nut and regulator not fully connected
Turning the coupling nut about one-half to three quarters additional turn until
solid stop.
Tighten by hand only-do not use tools.
Obstruction of gas flow
Clear burner tubes, per cleaning instruction on www.BlueRhino.com
Spider webs or insect nest in venturi
Clean venturi and burner tube, per cleaning instruction on www.BlueRhino.com
Burner ports clogged or blocked
Clean burner ports, per cleaning instruction on www.BlueRhino.com
Sudden drop in gas flow or reduced flame height
Out of gas
Replace LP gas tank
Excess flow valve tripped; safety device may have been
activated
1. Turn control knob to “OFF ”
2. Wait 30 seconds and light grill
3. If flames are still too low, reset the excessive flow safety device:
a. Turn control knob “OFF ”
b. Remove LP gas tank
c. Wait 1 minute
d. Attach LP gas tank
e. Perform a leak check per “Checking for Leaks” instructions in the owner’s
manual
f. Light grill per “Lighting Instructions” instructions in the owner’s manual
Irregular flame pattern, flame does not run the
full length of burner
Burner ports are clogged or blocked
Clean burner ports, per cleaning instruction on www.BlueRhino.com
Flame blow out
High or gusting winds
Do not use grill in high winds
Low on LP gas
Replace LP gas tank
Excess flow valve tripped; safety device may have been
activated
Refer to “Sudden drop in gas flow or reduced flame height”
Flame seems to lose heat when burning in cold
weather - temperature below 50ºF
Ice has built up on the outside of the LP gas tank
because the vaporization process is too slow.
1. Turn control knob to “OFF”
2. Remove LP gas tank per “Disconnect LP Gas Tank” instructions
3. Attach LP gas tank per “Conncet LP Gas Tank” instructions
4. Perform a leak check per “Checking for Leaks” instructions
5. Light grill per “Lighting Instructions” instructions
For more assistance please visit us online at www.BlueRhino.com or call 1.800.762.1142.