background image

EN 8

UTV-95

5.  Press MODE on the display will start flashing digit indicating in what time 

will start activated snooze (from 1 minute to 20 minutes);

6.  Press MODE to return to the normal display mode.

    In normal display mode, Press MODE, AL will be shown on the display, press 

UP to turn on or turn off the alarm.

   Pressing SNOOZE/LIGHT during the system activation will switch on the 

snooze.The snooze signal will be repeated (default) every 8 minutes unless it 

is previously deactivated with any button (except for SNOOZE/LIGHT ).

• WEATHER FORECASTS AND MOON PHASES

   This unit is capable of detecting outdoor temperatures and humidity chang

-

es. Based on collected weather data, it forecasts the weather for the next 12 

to 24 hours as next icons:

SUNNY -  , SLIGHTLY CLOUDLY - 

, CLOUDED - 

, RAINLY - 

)

Note:

 The  weather  forecast  accuracy  is  approximately  70%. The  weather 

station shows the forecasted (predicted), not the current conditions. 

Note2:

 The SUNNY icon indicates clear weather, even when in the night-time.

   Temperature and humidity are measured automatically and don’t need to 

operate. If display incorrect check/replace the batteries. Place the sensor away 

from any possible sources of heat/cold.

   The display show “LL” instead number values when the temperature or hu

-

midity is lower than the range of values set in the unit.

     The  display  show  “HH”  instead  number  values  when  the  temperature  or 

humidity is higher than the range of values set in the unit.

  The station displays also relevant moon phases.

• Signal reception channel

    UP button can be used to set the sensor the signal is received from. Chan

-

nels 1,2 or 3 can be set subsequently.

• Comfort level indicator

   Depending on weather conditions in the room, the weather station may dis

-

play what follows:

- comfort  

 (humidity range 40% - 70%, indoor temperature 20°C - 28°C);

- dry      

 

(humidity below 40%) – unfavorable conditions;

- humid     

 

(humidity over 70%) – unfavorable conditions. 

• Minimum and maximum temperature and humidity indications

1.  Press MAX/MIN button to display the highest outdoor/indoor temperatures 

and humidity, (from the last weather station resetting). MAX caption will be 

displayed at the temperatures and humidity;

2.  Press MAX/MIN button again to display the lowest outdoor/indoor tempera

-

tures and humidity, MIN caption will be displayed;

3. Press MAX/MIN button again to come back to displaying the current tem

-

peratures and humidity or wait 7-8 seconds until the weather station auto

-

matically returns to displaying current indications. Max and Min symbols will 

disappear.

• SELECTING THE TEMPERATURE DISPLAY UNIT (°C/°F)

    Press DOWN to set the required temperature unit: degrees Celsius or de

-

grees Fahrenheit (°C/°F).

• SPECIFICATION

Main unit:

Indoor temperature measuring range:         -9.9°C to 50°C (14 °F to 122°F)

Outdoor temperature measuring range:         -40°C to 60°C (-40°F to 140°F)

Tolerance/accuracy of temperature measurement:   +/- 1.1°C (+/-2°F)

Humidity measurement range:   

       

20% ~ 90%

Accuracy of humidity measurement:  

       

+/-5%

Batteries:   

 

 

       

2x1.5V / AAA (LR03 )

Size: 

 

 

 

 

128 * 90 * 58 mm

Weight:    

 

 

 

130 g

Wireless sensor:

Distance of open air transmission:  

       

30 m max.

Frequency band:    

 

       

433 MHz

Temperature measurement range:  

      -40°C do 60°C (-40°F do 140°F)

Tolerance/accuracy of temperature measurement:   +/- 1.1°C (+/-2°F)

Batteries:   

 

 

       

2x1.5V / AAA (LR03 )

Size: 

 

 

 

 

93 * 60 * 23 mm

Weight:    

 

 

 

62 g

• PACKAGING CONTENT

1.  Wireless weather station

2.  Single wireless sensor

3.  Instructions for Use

Содержание UTV-95

Страница 1: ...Ltd Office address Xingqiao North Road 161 Xingqiao Development Zone Linping Hangzhou city Zhejiang province 311110 PRC Tel 86 571 86262828 Wireless Weather Station with Weather Forecast Indoor Outdoo...

Страница 2: ...RU 2 UTV 95 c 433...

Страница 3: ...RU 3 UTV 95 0 50 o 70 50 2 7 1 SNOOZE LIGHT 2 MODE 3 UP 4 DOWN 5 MAX MIN 6 LIGHT SNOOZE 1 CHANEL 1 2 3 1 2 3 1 2 CHANEL 1 2 3 CHANEL 1 3 2 3 4 1 2 10 3 3...

Страница 4: ...RU 4 UTV 95 20 30 1 MODE 3 2 DOWN UP 3 3 MODE 12 24 4 DOWN UP 5 MODE 2 1 MODE 3 2 DOWN UP 3 MODE 4 DOWN UP 5 MODE 6 DOWN UP 1 20 MODE MODE AL UP SNOOZE LIGHT 8 24 1 2...

Страница 5: ...70 30 4 5 6 7 LL HH DOWN C F UP 1 2 3 40 70 20 C 28 C 40 70 1 MAX MIN MAX 2 MAX MIN MIN 3 MAX MIN 8 9 9 50 14 F 122 F 20 90 1 1 2 F 5 1 5 2 A 128 90 58 130 40 60 40 F 140 F 1 1 2 F 433 3 30 1 5 2 93 6...

Страница 6: ...facturer and or importer shall not be liable for any claim of any kind whatsoever against the use of these materials by any other party DISPOSING AND CARE OF THE UNIT This multi function unit has Wire...

Страница 7: ...30 meters in opened area The remote temperature sensor can be placed indoors or outdoors depend ing on the area where the temperature is intended to be measured If you intend to measure outdoor condit...

Страница 8: ...is received from Chan nels 1 2 or 3 can be set subsequently Comfort level indicator Depending on weather conditions in the room the weather station may dis play what follows comfort humidity range 40...

Страница 9: ...of surfaces deformations and so on natural wear of the parts having limited service life on product prevention and also on expendables actions of force majeure fire accident malfunction of an electric...

Страница 10: ......

Отзывы: