84
Van Cort Patrol C
935. 0125MHz
NFW P25
E R R : 1 4 8 A U T O
T 1.38 1.60 1.82
Current Threshold Setting
Threshold Voltage Level
The first line on the display will show the digital error rate and the decode threshold
setting (0-20) when receiving. The second line on the display shows the decode
threshold levels.
Allow the scanner to monitor the site or frequency for several minutes. Press
Func
and rotate the Scroll Control to change the decode threshold level setting and obtain
the lowest error rate possible when receiving transmissions. Whatever you set at
this point will be remembered as the starting point for the auto-tuning function for
subsequent transmission.
To exit P25 Adjustment Mode press
Vol
.
See also the following settings to make adjustments P25 Waiting Time, P25 LP Filter,
and P25 Threshold.
LOCKING/UNLOCKING SYSTEMS/SITES/SEARCHES
With the advent of multi-site trunking, you can no longer lockout a trunking system.
You have to lockout the site(s) assigned to the system. You can still lockout
conventional systems and searches the same way. Also, with the ability now to
assign quick keys the searches you can turn them off and on or lockout/unlock them
just like conventional systems and trunked sites.
Remember, unlocking or locking out a system/site/search is not the same thing as
enabling/disabling it (turning the quick key on or off).
To Lock out a Conventional System/Trunked Site/Search in Scan Mode
hold
on any channel/frequency in the system/site/search, press
Func
then
L/O
to toggle
‘Unlocked’, ‘Temporary L/O’, or ‘Lockout’. Press
Hold
to resume.
Note: ‘Temporary Lockout’ means unlocked the next time you cycle power the
site/system/search will be unlocked.
Or, use
Menu
to drill down to the system/site/search options and lock it out there.
See ‘Edit Conventional System Options’, ‘Edit Site Options’, ‘Edit Service Search’, or
‘Edit Custom Search’.
To Unlock a Conventional System/Trunked Site/Search in Scan Mode
press and
hold
Func
to ‘lock’ function mode.
Содержание BCD325P2
Страница 1: ...BCD325P2 Owner s Manual 2015 Uniden America Corporation Printed in Vietnam U01UB379ZZZ 0...
Страница 8: ...8...
Страница 28: ...28 A LOOK AT THE DISPLAY Conventional Display Mode 1 Function Mode Conventional Display Mode 2...
Страница 29: ...29 Trunking Display Mode 1 Trunking Display Mode 2...
Страница 69: ...69 Alert in GPS Display Mode...
Страница 87: ...87 BAND SCOPE MODE...
Страница 132: ...132...