2-3.
Tuning Coil Alignment
(
1
) Connect SSG output and mV as 2-2 (1), (2).
(
2
) Set PRESELECT CONTROL to center position.
(
3
) Select BAND SWITCH and SEGMENT SWITCH in order, starting from
15.0 MHz according to the chart 2-2-1-A, and also provide listed frequency
signals (unmodulated 40 dB) from SSG as show in the chart 2-2-1-B and recive
them by tuning the main dial.
(
4
) Get maximum S-Meter or mV readings by adjusting tuning coils as indicated
(L201 – L213) on each band.
(
5
) Control SSG output during this process to make adjustment easier.
Chart 2-2-1
A
B
C
BAND
SEGMENT
FREQ. (MHz)
COIL No.
15.0
0/500
15.000
L201, L208
3.5
100/600
3.600
L202, L209
7.0
100/600
7.100
L203, L210
14.0
200/700
14.200
L204, L211
21.0
200/700
21.200
L205, L212
28.5
0/500
28.500
L206, L213
2-4.
IF Tuning Coil Alignment.
(
1
) Connect SSG and mV as 2-2 (
1
), (
2
)
(
2
) Set BAND SWITCH to 14.0, and SEGMENT SWITCH to 200/700.
(
3
) Provide 40 dB of 14.200 MHz unmodulated signal from SSG.
(
4
) Tune the main dial and receive the input signal, then control PRESELECT
knob to get maximum output readings.
(
5
) Adjust L214 – L218 so as to get the maximum readings on S-Meter or mV.
Содержание 2020
Страница 20: ...UNIDEN 2020 Sid 20 26 0 1 uS DIV 0 1 uS DIV 5 uS DIV 5 uS DIV 0 5 uS DIV 0 5 uS DIV 1 A 1 B 1 A 1 C 1 D 1 D 1 C...
Страница 21: ...UNIDEN 2020 Sid 24 26 PLL Unit PC 086 Operation Unit PC 085...
Страница 22: ...UNIDEN 2020 Sid 21 26 1 E 1 F 1 G 1 H 1 H...
Страница 23: ...UNIDEN 2020 Sid 22 26 5 uS DIV 0 1 uS DIV 0 1 mS DIV 5 uS DIV 0 1 mS DIV 1 I 1 I 1 J 1 J 1 K...
Страница 24: ...UNIDEN 2020 Sid 23 26 2 C 2 B 2 D 2 A 2 D 20 Us DIV 0 1 Us DIV 1 Us DIV 0 1 Us DIV 20 Us DIV 20 Us DIV...
Страница 25: ...UNIDEN 2020 Sid 25 26...
Страница 26: ...UNIDEN 2020 Sid 26 26...