Warranty: 

 
This instrument is warranted against defects in materials and workmanship for a period of 
one (1) year from the date of shipment to the customer. This warranty is limited to the 
repair and replacement of parts, which prove to be defective during the warranty period. 
This warranty is not valid for parts damaged, lost, or which fail because of accident, fire, 
theft, acts of nature, negligence, or the use of chemicals, which have a deleterious effect. 
This warranty is conditioned upon the manufacturer retaining the option of replacing parts 
up to and including the entire instrument. 
 
Note: This warranty will not extend to any repairs or modifications made to the instrument 
by some party other than the manufacturer or a party authorized by Unico. Also, this 
warranty shall be in effect only upon the notice of the defect to the manufacturer or it’s 
authorized distributor, or dealer, within five (5) days after the occurrence of said defect 
No other warranty of any kind is made expresses or implied. The warranty described 
above shall be the sole and exclusive remedy available to the purchaser. Correction of 
defects, in the manner and for the period of time described above, shall constitute 
complete fulfillment of all liabilities and responsibilities of the manufacturer to the 
purchaser with respect to the product, and shall constitute full satisfaction of all claims, 
whether based on contract, negligence, strict liability or otherwise. In no event shall the 
manufacturer be liable, or in any way responsible for any damages or defects in the 
product that were caused by repairs or attempted repairs performed by anyone other than 
the manufacturer’s dealer or station, nor shall the manufacturer be liable or in any way 
responsible for any incidental or consequential economic or property damages. Some 
states do not allow the exclusion of incidental or consequential damage, so the above 
exclusion may not apply to you. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание PowerSpin C8624

Страница 1: ...PowerSpin C8624 24 Place Centrifuge OPERATION MANUAL 182 Ridge Road Suite E Dayton NJ 08810 USA 800 588 9776 Fax 732 274 1151 Web www unicosci com...

Страница 2: ...tal display simultaneously Electronic 60 minutes timer with beeping signal at end of run Automatic time and speed reset to the last time speed and time setting for repeated job Memorized time and spee...

Страница 3: ...shion foam in the rotor chamber Do not operate the centrifuge before the foam is removed 1 Take the centrifuge from the Styrofoam and place it on a sturdy flat surface Do not turn on the centrifuge 2...

Страница 4: ...conds To increase time setting press and hold up arrow otherwise down arrow button Speed Setting and Speed Setting Change Speed setting Use the up or down arrow to preset the running speed The speed r...

Страница 5: ...total to date number of cycles will be displayed Note Cycles of usage is not total spinning time It represents the total times the centrifuge has spun Operation 1 Plug the centrifuge into a power sou...

Страница 6: ...is not necessary A surface cleaner such as Formula 409 can be used to clean the outside of the instrument The rotor chamber and cover can be disinfected with a mild solution of bleach or other disinfe...

Страница 7: ...switch in the back of unit is in the on position e Check that the power indicator light with the switch is lit A failure of the power light to illuminate could indicate a need for a new fuse when the...

Страница 8: ...which is 250V 4A e Put the snap in fuse holder back 5 Intermittent motor operation or no operation Contact your representative for possible motor replacement Specifications Speed 1 000 3 400 RPM Spee...

Страница 9: ...ed distributor or dealer within five 5 days after the occurrence of said defect No other warranty of any kind is made expresses or implied The warranty described above shall be the sole and exclusive...

Страница 10: ...o response no response sound 1 Loose connection or connection reversed 2 Touch panel defective 1 Exercise the connector J2 on main 2 Replace touch panel 6 Display show Running but motor is not running...

Страница 11: ...4 Centrifuge Parts and Nomenclature Lid Rotor Emergency lid opening left side Control panel Start Stop Open buttons Digital Timer Speed Control Safety lock On off switch on back side Power indicator M...