Bulletin 30-121.019
14
Copyright © 2015 Unico, Inc.
(SAC 37.4255.109.02)
Minimum operation and maintenance area. Allow
generous clearance for servicing and to avoid air
recirculation. Air flow should be away from building.
Provide a solid base for outdoor unit raised from the
ground level. Fix unit to base using 4 anchor bolts.
Heat pump drain connection. Use, if necessary, the
accessories supplied. Remove plug and insert drain
connection. Then attach plastic tube to the drain
connection by slipping over the barbed end. Use 3/4 inch
(18 mm) plastic tubing.
Plug the other hole with the plastic cap.
Remove the side cover, to connect the refrigerant
lines and wiring. Connect the refrigerant lines first.
Then connect the power line and interconnecting wires to
outdoor unit on the terminal strip and secure them with
clamps.
IS30G080
Use insulated copper tube. Cut approximate 12-20
inches (30-50 cm.) longer than actual distance
between units.
Remove burrs at the ends of the copper tubes. Hold
the tube end downward and be sure that no dirt falls
into the tube.
16"
(400)
60"
(1500)
12"
(500)
80"
(2000)
80"
(2000)
4"
(100)
12"
(500)
Dimensions in inches (mm)
4"
(100)
16"
(400)
4"
(100)
Insulation
min. 5/16" (8 mm)
min. 5/16" (8 mm)
OUTDOOR UNIT INSTALLATION
B
A
C
D
E
F
Содержание IS18G050
Страница 34: ...Bulletin 30 121 019 34 Copyright 2015 Unico Inc SAC 37 4255 109 02 Model ISG65...
Страница 35: ...Bulletin 30 121 019 35 Copyright 2015 Unico Inc SAC 37 4255 109 02 Model IS30G080...
Страница 45: ...Bulletin 30 121 019 45 Copyright 2015 Unico Inc SAC 37 4255 109 02 IS18G050 IS24G065 REFRIGERANT CIRCUITING...
Страница 46: ...Bulletin 30 121 019 46 Copyright 2015 Unico Inc SAC 37 4255 109 02 IS30G080 IS36G110...